Site Preparation 8
Elect rical Requir ements
T
he electrical supply should be located within th e shaded
area shown in the illu strations below. Follo w the National
Electrical Code and local codes and ordinances when
installing the rec eptacle. A separate circuit, servicing only
this appliance is re quire d. A grou nd fault circuit interrupter
(GFCI) is not recomm ended and may cause interruption of
operation.
IMPORTANT NOTE: It is critical that the electr ical outlet be
located within the shaded area shown so it does not inter-
fere with installa tion of the anti-tip bracket. It must b e
flush with the back wall and positioned with the grounding
prong to the right of th e thinner blades.
Ele ctrical Requirements
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type
Do not use an extension cord or two-prong adapter.
Do not remove the power supply cord ground prong.
The outlet must be checked by a qualified electrician
to be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.