Electronic Control System
Under Counter (UC-24) Series
3-22
#7003933 - Revision B - November, 2007
Clearing Non-Flashing “SERVICE” and Error Codes
If Error Codes are observed in Diagnostic Mode, a non-flashing
SERVICE icon will appear on the LCD when
Diagnostic Mode ends, indicating error codes are still stored (See Figure 3-38). To clear a non-flashing SERVICE
icon and the error codes, the problem must be corrected and the unit must be ON, then:
On a model UC-24C: Press the Freezer
WARMER and COLDER keys for fifteen (15) seconds, and the error
codes are cleared. (See Figure 3-39)
On a model UC-24B, UC-24R or UC-24RO: Press the Refrigerator
WARMER and COLDER keys for fifteen (15)
seconds, and the error codes are cleared. (See Figure 3-40)
Figure 3-38. Non-flashing SERVICE after Diagnostic Mode = Error Codes are Stored
Figure 3-39. (Model UC-24C) Clear Non-Flashing SERVICE.
With Unit ON, Press and Hold the Freezer WARMER and COLDER Keys for 15 Seconds
Figure 3-40. (Model UC-24B, UC-24R, UC-24RO) Clear Non-Flashing SERVICE.
With Unit ON, Press and Hold the Refrigerator
WARMER and COLDER Keys for 15 Seconds
UC-24C:
Press & Hold
for 15 Seconds
UC-24R, UC-24RO, UC-24B:
Press & Hold
for 15 Seconds

Related product manuals