EasyManuals Logo

Suburban DYNALINE DL3-0912 User Manual

Default Icon
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
Suburban DynaLine Owner's Manual 10/2017 Rev.1 12
C
S
BR
Y
R
Y
COMPRESSOR
MOTOR
BR
ROOM AIR
BR
BK
EXHAUST
MOTOR
BK
MOTOR
BR BR
2
4
3
1
IGNITOR
10
11
12
7
8
9
4
5
6
1
2
3
TRANSFORMER
24V
1L
TERM.
BLOCK
L 2
BK
BK
R
PRESSURE
HI LIMIT
SW. N.C.
SW. N.O.
VALVE
O
TEMP.
SENSE
BK
BK
W
W
Y
Y
BK
BL
Y
BK
Y
R
R
R
R
O
BR
BK
BK
COMPRESSOR
RELAY
Y
Y
L2
R
BK
L1
WHITE
YELLOW
BROWN
BLACK
RED
BLUE
ORANGE
COLOR
R
W
Y
BR
BL
BK
CODE
O
FLAME
CONDENSER
BK
BL
MODULE
BOARD
O
BR
1234
(BUILT-IN T-STAT)
PROBE
O
DE-ICER
SW.
R
R
BK
NOTE: ALL WIRES ARE 18 A.W.G. UNLESS OTHERWISE SPECIFIED.
MAXIMUM RATING OF SUPPLY CIRCUIT PROTECTIVE DEVICE 15 AMPS.
IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THE APPLIANCE MUST BE
REPLACED, IT MUST BE REPLACED WITH TYPE 105ĀC WIRE OR TYPE 150ĀC WIRE
WHERE SPECIFIED OR ITS EQUIVALENT.
105ĀC THERMOPLATIC 14 A.W.G. WIRE
TGS 200°C 18GA STRANDED TEFLON COATED
N.C.
FLUE LIMIT
R
HIGH
LOW
L1 COMB COND
BLWR
FLAME
DOWNPWR
FAN
MED
BK
BK
Y
R
C 208 230
TRANSFORMER
120V
W/BK
W
BK
BK
R
BK
O
BK
PRESSURE
SW. N.C.
81872
BK
BK
R
R
W/BK
WHITE/BLACK
2
4
3
1
BL
BL
W
W
BK
IGNITOR
RELAY
BK
ROCKER
SWITCH
BK
BL
R
R
O
O
24VAC
GND
CONT
GAS
VALVE
POWER SUPPLY BOARD CO DETECTOR
BL
Y
BK
GY
R
BL
T
T
NC
C
T
C
A
NO
(+)
(-)
(+)
(-)
BR
BL
BL
Y
Y
BR
O
4
3
2
1
BL
O
O
Y
GREY
GY
LOCKING
CONNECTOR
C 208 230
G
CHAMBER
BURNER
CORRECT FLAME
BURNER OBSERVATION
WINDOW
ORANGE OUTER CONE
WELL DEFINED PATTERN
BURNER
CHAMBER
INCORRECT FLAME
BURNER OBSERVATION
WINDOW
YELLOW OUTER FLAME
ERRATIC PATTERN
ORANGE, YELLOW INNER FLAME
ERRATIC PATTERN
CHAMBER
BURNER
CORRECT FLAME
BURNER OBSERVATION
WINDOW
ORANGE OUTER CONE
WELL DEFINED PATTERN
BURNER
CHAMBER
INCORRECT FLAME
BURNER OBSERVATION
WINDOW
YELLOW OUTER FLAME
ERRATIC PATTERN
ORANGE, YELLOW INNER FLAME
ERRATIC PATTERN
REMOVE (4) STICKERS FROM BRACES
& REMOVE BRACES
RETIRER LES QUATRE (4) VIS DES
SUPPORTS ET RETIRER LES SUPPORTS
REMOVE (2) SCREWS & REMOVE
CONDENSER COVER
RETIRER LES DEUX (2) VIS ET RETIRER
LE COUVERCLE DU CONDENSEUR
A
B B
WITH CARBON MONOXIDE DETECTOR
Figure 15b
Figure 16
Figure 17

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suburban DYNALINE DL3-0912 and is the answer not in the manual?

Suburban DYNALINE DL3-0912 Specifications

General IconGeneral
BrandSuburban
ModelDYNALINE DL3-0912
CategoryAir Conditioner
LanguageEnglish

Related product manuals