INTRODUCTION
1.YourDrop-inCooktophasbeencertiedbyCSAfortheU.S.A.and
CanadaforusewithLP/Propanegasonly.
2.Yourcooktopisoneofthefollowingmodels:SDN2orSDN3.
3.Modelnumberletterdesignation:
S - Suburban
D - Drop-in
N-Newdesign
#-Numberofburners
4.Thecompletemodel,serialnumberand stocknumberare located
ontheCSAlabellocatedunderthetop.Thisinformationwillbeneeded
when servicing appliance or ordering parts. Record the information
below and retain for future reference. Replacement parts can be
ordered through your local dealer or Suburban Service Center. To
obtain information on locating a local service agency, call Suburban
Manufacturing Company, Customer Service Department, (423) 775-
2131.
ModelNo. ______________________________________________
Stock No. ______________________________________________
SerialNo. _______________________________________________
DateofPurchase _________________________________________
5.ThecooktopisdesignedcertiedforusewithLP/Propanegasonly.
Do not attempt to convert to natural gas.
6.Gassupplypressureforcheckingoftheregulatorsettingshallbeat
least1”W.C.abovethesuggestedmanifoldpressure.
MinimumGasSupplyPressure-11”W.C.
MaximumGasSupplyPressure-14“W.C.
INSTALLATION
WARNING! Installation of this appliance must be made in
accordance with the written instructions provided in this
manual. No agent, representative or employee of Suburban or
other person has the authority to change, modify or waive any
provision of the instructions contained in this manual.
1.IntheU.S.A.,theinstallationmustconformwithstateorothercodes
orintheabsenceofsuchcodes,refertothelatesteditionof:
a. StandardforRecreationalVehiclesNFPA1192.
b.NationalFuelGasCodeANSIZ223.1/NFPA54
InCanada,theinstallationmustbeinaccordancewith:
a.StandardCAN/CSA240.4.2-08,InstallationRequirementsfor
PropaneAppliancesandEquipmentinRecreationalVehicles.
b.Anyapplicablelocalcodesandregulations
2.Minimum clearances from combustible walls above and below
counter:
Models
BelowCounter CenterofBurnerHead(s)toadjacentvertical
combustiblematerialabovethecookingsurface
burners.
Sides,Rearand
Bottom
RightSidewall LeftSidewall Backwall
SDN2 0” 57/8” 57/8” 8”
SDN3 0” 55/8” 6” 8”
3.Cut-outdimensionsillustratedinFigure2areasfollows:
Model
Dimensions
A B C* D* E
SDN2 163/8 115/8 23/16 3/4”min. 18”
SDN3 1815/16 161/8 21/16 23/8”min. 21”
*Minimumacceptablespacingbetweenadjacentmodelsis3inches.
WARNING: Installation of cook top cannot be such that the user
is required to reach over any of the burners to reach the knobs.
4.Beforeplacingdrop-incooktopintocabinet,determinewhichone
ofthethreeknockoutopeningsintheburnerbox(leftside,rightsideor
rear)willbeusedforroutingofthegassupplytubingtothepressure
regulator.Aftermakingselection,knockoutthe1inchplug.Placedrop-
incooktopintothepreparedopeningandsecuretocabinetwithfour(4)
woodscrews.(Notprovided)
NOTE: For models with a manifold extension, place the drop-in
cook top into the prepared opening and secure to the cabinet with
four (4) wood screws. (Not provided)
5.Routegaslinethroughopeninginburnerboxandconnectthegas
linetothe3/8”arettinginsidetheburnerbox.Placenylonbushing
overgaslineandinsertbushingintoopeninginburnerbox.
NOTE: For models with a manifold extension, connect the gas
line to the tting just outside the burner box. Be sure to hold the
tting on the extension with a wrench when tightening the gas
connection. Failure to hold tting secure could result in a gas leak
due to tting being damaged.
CAUTION: Gas supply tubing within the connes of the appliance
connection shall be rigid or semirigid metallic tubing.
6.Besureallopeningsinthecabinetsaroundthegaslinearesealedat
timeofinstallation.
CAUTION: It is imperative that the cabinet in which the cook
top is placed be separated from other appliances so that the
combustion air supply to the top burners can not be affected
in any way by any forced-air heating appliance or its return
air system or by any other source of positive or negative air
pressure. A negative air pressure created by another forced air
appliance may draw the ame down around the top burners
and into the cook top resulting in damage to the burners and
cook top, as well as possible personal injury and/or damage to
vehicle. A positive draft could cause the burner ame to lift-off
the burner and go out resulting in an uncontrolled escape of
gas. Whenever the gas fumes reach an open ame or another
ignition source, an explosion and/or re will occur resulting in
property damage, personal injury and/or loss of life.
7.Besureburnerknobsarein“off”position.Turnongassupply.Check
allconnectionsforleaks.
WARNING: Never check for leaks with an open ame. Apply a
soap and water solution to all joints to see if bubbles are formed.
NOTE:Theappliancemustbedisconnectedfromthegassupplypiping
systemduringanypressuretestingofthatsystemattestpressurein
excessof1/2PSIG.
CSA LABEL
ÉTIQUETTE CSA
Figure 1
2