1.YourDrop-inCooktophasbeencertiedbyCSAfortheU.S.A.and
CanadaforusewithLP/Propanegasonly.
2.Yourcooktopisoneofthefollowingmodels:SDN2orSDN3.
3.Modelnumberletterdesignation:
S - Suburban
D - Drop-in
N-Newdesign
#-Numberofburners
4.Thecompletemodel,serialnumberand stocknumberare located
ontheCSAlabellocatedunderthetop.Thisinformationwillbeneeded
when servicing appliance or ordering parts. Record the information
below and retain for future reference. Replacement parts can be
ordered through your local dealer or Suburban Service Center. To
obtain information on locating a local service agency, call Suburban
Manufacturing Company, Customer Service Department, (423) 775-
2131.
ModelNo. ______________________________________________
Stock No. ______________________________________________
SerialNo. _______________________________________________
DateofPurchase _________________________________________
5.ThecooktopisdesignedcertiedforusewithLP/Propanegasonly.
Do not attempt to convert to natural gas.
6.Gassupplypressureforcheckingoftheregulatorsettingshallbeat
least1”W.C.abovethesuggestedmanifoldpressure.
MinimumGasSupplyPressure-11”W.C.
MaximumGasSupplyPressure-14“W.C.
INSTALLATION
WARNING! Installation of this appliance must be made in
accordance with the written instructions provided in this
manual. No agent, representative or employee of Suburban or
other person has the authority to change, modify or waive any
provision of the instructions contained in this manual.
1.IntheU.S.A.,theinstallationmustconformwithstateorothercodes
orintheabsenceofsuchcodes,refertothelatesteditionof:
a. StandardforRecreationalVehiclesNFPA1192.
b.NationalFuelGasCodeANSIZ223.1/NFPA54
InCanada,theinstallationmustbeinaccordancewith:
a.StandardCAN/CSA240.4.2-08,InstallationRequirementsfor
PropaneAppliancesandEquipmentinRecreationalVehicles.
b.Anyapplicablelocalcodesandregulations
2.Minimum clearances from combustible walls above and below
counter:
Models
BelowCounter CenterofBurnerHead(s)toadjacentvertical
combustiblematerialabovethecookingsurface
burners.
Sides,Rearand
Bottom
RightSidewall LeftSidewall Backwall
SDN2 0” 57/8” 57/8” 8”
SDN3 0” 55/8” 6” 8”
3.Cut-outdimensionsillustratedinFigure2areasfollows:
Model
Dimensions
A B C* D* E
SDN2 163/8 115/8 23/16 3/4”min. 18”
SDN3 1815/16 161/8 21/16 23/8”min. 21”
*Minimumacceptablespacingbetweenadjacentmodelsis3inches.
WARNING: Installation of cook top cannot be such that the user
is required to reach over any of the burners to reach the knobs.
4.Beforeplacingdrop-incooktopintocabinet,determinewhichone
ofthethreeknockoutopeningsintheburnerbox(leftside,rightsideor
rear)willbeusedforroutingofthegassupplytubingtothepressure
regulator.Aftermakingselection,knockoutthe1inchplug.Placedrop-
incooktopintothepreparedopeningandsecuretocabinetwithfour(4)
woodscrews.(Notprovided)
NOTE: For models with a manifold extension, place the drop-in
cook top into the prepared opening and secure to the cabinet with
four (4) wood screws. (Not provided)
5.Routegaslinethroughopeninginburnerboxandconnectthegas
linetothe3/8”arettinginsidetheburnerbox.Placenylonbushing
overgaslineandinsertbushingintoopeninginburnerbox.
NOTE: For models with a manifold extension, connect the gas
line to the tting just outside the burner box. Be sure to hold the
tting on the extension with a wrench when tightening the gas
connection. Failure to hold tting secure could result in a gas leak
due to tting being damaged.
CAUTION: Gas supply tubing within the connes of the appliance
connection shall be rigid or semirigid metallic tubing.
6.Besureallopeningsinthecabinetsaroundthegaslinearesealedat
timeofinstallation.
CAUTION: It is imperative that the cabinet in which the cook
top is placed be separated from other appliances so that the
combustion air supply to the top burners can not be affected
in any way by any forced-air heating appliance or its return
air system or by any other source of positive or negative air
pressure. A negative air pressure created by another forced air
appliance may draw the ame down around the top burners
and into the cook top resulting in damage to the burners and
cook top, as well as possible personal injury and/or damage to
vehicle. A positive draft could cause the burner ame to lift-off
the burner and go out resulting in an uncontrolled escape of
gas. Whenever the gas fumes reach an open ame or another
ignition source, an explosion and/or re will occur resulting in
property damage, personal injury and/or loss of life.
7.Besureburnerknobsarein“off”position.Turnongassupply.Check
allconnectionsforleaks.
WARNING: Never check for leaks with an open ame. Apply a
soap and water solution to all joints to see if bubbles are formed.
NOTE:Theappliancemustbedisconnectedfromthegassupplypiping
systemduringanypressuretestingofthatsystemattestpressurein
excessof1/2PSIG.