EasyManua.ls Logo

Sullair 1112e - Lubrication Change Recommendations

Sullair 1112e
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1100E, 1500E, 1800E USER MANUAL SECTION 3
22
COMPRESSOR: STANDARD MODELS:
Type: Rotary Screw
Standard Operating Pressure:
100 psig (7 bar) 125 psig (9 bar) / 150 psig (10.0 bar)
175 psig (12.0 bar)
Bearing Type: Anti-friction
Ambient Temperature (Max.): 104ºF (40ºC)
Cooling: Pressuried Fluid
Compressor Fluid: Sullair Sullube
Separator/Sump Capacity: 1.8 Gallons (8.8 liters)
System Capacity: 2.5 Gallons (9.5 liters)
Control: WS Controller controller
(II) Special compressors are available for operation at higher pressures.
(Ill) Special compressors are available for operation in higher ambient temperature.
MOTOR (IV): STANDARD MODELS:
Size: 15, 20, 25HP / 11, 15, 18KW
Standard Operating Pressure:
TEFC, Epact Efficiency, Three Phase, 230/460 Hz, 380-
415 (400) 50 Hz
Ambient Temperature (Max.): 104ºF (40ºC)
Options Available: 200V and 575V 60 Hz, 220 50 Hz CE Approved
Starter Full Voltage Magnetic, Wye-Delta or Solid State
Options Available: VSD Optional, 460V, 575V, 400V 50 Hz
Speed - 15, 20, 25 HP: 1765 RPM (60 Hz) or 1455 RPM (50 Hz)
(IV) Multi-frequency and voltage motors are used. The compressors must be used only with the specified electrical
frequency and voltage.
NOTE
For latest sound test data, consult Sullair
Factory.

Other manuals for Sullair 1112e