®SULLAIR®
INDUSTRIAL AIR COMPRESSOR
1100E, 1500E, 1800E,
1100EV, 1500EV, 1800EV
11, 15 & 18KW/15, 20 & 25HP
Air-Cooled Standard & 24 KT
02250155_844_Cvr
PART NUMBER:
02250155–844
KEEP FOR
FUTURE
REFERENCE
©
SULLAIR CORPORATION
The information in this document is
correct at the time of printing for utility
compressor serial number
20060601XXXX
and all subsequent serial numbers.
OPERATORS MANUAL AND PARTS LIST

Table of Contents

Other manuals for Sullair 1509e

Questions and Answers

  • B
    Brandon CarlsonAug 8, 2025
    Why is my Sullair 1509e Air Compressor not building full discharge pressure?
    • M
      mwarnerAug 8, 2025
      If your Sullair Air Compressor isn't building full discharge pressure, consider these potential causes: The air demand might be too great, so check service lines for leaks or open valves. The air filter might be dirty, so inspect the filter indicator and replace the element if needed. A plugged inlet valve bleed orifice could also be the problem, so ensure the control line bleed orifice is not blocked. Additionally, the pressure regulator might be out of adjustment or defective, so adjust it or replace the diaphragm if necessary. Finally, a defective unload solenoid valve could be the issue, so check that it closes when energized, and replace it if defective.
  • X
    xwongAug 18, 2025
    Why won't my Sullair 1509e Air Compressor start?
    • K
      karencolonAug 18, 2025
      If your Sullair Air Compressor won't start, several factors could be the cause. First, check that the main disconnect switch is closed. Another possible cause is a blown line fuse, which would need to be replaced. Also, the motor starter overload might have tripped; try resetting it, and if the issue continues, inspect the motor starter contacts. Finally, low incoming line voltage could be the culprit, so check the voltage and consult your power company if it's too low.
  • P
    Paul MaldonadoNov 27, 2025
    What to do if my Sullair 1509e shuts down with air demand present?
    • L
      Latoya FordNov 27, 2025
      If your Sullair Air Compressor shuts down while there's still air demand, there are several potential reasons. It could be due to a loss of control voltage; try resetting it, and if the problem continues, ensure the line pressure doesn't exceed the compressor's maximum operating pressure. Low incoming voltage can also cause this issue, so consult your power company. Other possibilities include the separator needing maintenance (check the indicator under full load), a high pressure setting in the WS controller (reset it), a defective unload solenoid valve (repair if defective), or a defective blowdown valve (repair if defective). Restricted cooling air flow (clean the cooler and check ventilation), high ambient temperature (improve ventilation), low fluid level (add fluid), or a malfunction...

Summary

SECTION 1 SAFETY

1.4 FIRE AND EXPLOSION

Precautions to prevent fires and explosions, including spill cleanup and ignition sources.

1.5 MOVING PARTS

Safety measures to avoid injury from the compressor's moving components like fans and couplings.

1.8 ELECTRICAL SHOCK

Safety instructions for electrical installation, maintenance, and avoiding shock hazards.

1.9 LIFTING

Guidelines for safely lifting and moving the compressor unit using appropriate equipment.

SECTION 2 DESCRIPTION

2.2 DESCRIPTION OF COMPONENTS

Identification and explanation of the main components and assemblies of the air compressor package.

2.3 SULLAIR COMPRESSOR UNIT, FUNCTIONAL DESCRIPTION

Detailed functional description of the single-stage, flood-lubricated rotary screw compressor unit.

2.4 COMPRESSOR COOLING AND LUBRICATION SYSTEM, FUNCTIONAL DESCRIPTION

Explanation of how the cooling and lubrication system, including fluid flow, operates.

2.5 COMPRESSOR DISCHARGE SYSTEM, FUNCTIONAL DESCRIPTION

Description of the receiver tank's functions and the compressed air/fluid mixture handling.

2.6 CONTROL SYSTEM, FUNCTIONAL DESCRIPTION

Explanation of the compressor's control system and its operation in different modes.

2.7 AIR INLET SYSTEM, FUNCTIONAL DESCRIPTION

Description of the air inlet system, including the air filter and modulating inlet valve.

SECTION 3 SPECIFICATIONS

3.7 WIRING DIAGRAMS

Electrical wiring diagrams for different compressor configurations (MFV, VSD).

SECTION 4 INSTALLATION

4.1 MOUNTING OF COMPRESSOR

Guidelines for establishing a suitable foundation and properly mounting the compressor unit.

4.2 VENTILATION AND COOLING

Requirements for adequate space and airflow for proper ventilation and cooling of the compressor.

4.6 ELECTRICAL PREPARATION

Customer responsibilities for electrical supply, grounding, and wiring connections.

4.7 MOTOR ROTATION DIRECTION CHECK

Method to verify correct motor rotation direction during initial startup.

SECTION 5 WS CONTROLLER

5.3 LCD DISPLAY

Explanation of the information displayed on the LCD screen, including status and fault messages.

SECTION 6 MAINTENANCE

6.5 FLUID FILTER MAINTENANCE

Steps for replacing the fluid filter element when indicated or during fluid changes.

6.6 AIR FILTER MAINTENANCE

Procedures for maintaining and replacing the air filter element when the gauge shows red.

6.9 TROUBLESHOOTING GUIDE

A guide listing common symptoms, probable causes, and remedies for compressor issues.

SECTION 7 PARTS LISTS

Sullair 1509e Specifications

General IconGeneral
Model1509e
TypeRotary Screw
Voltage460 V
Phase3
Operating Pressure125 PSIG
Max Pressure150 psig (10.3 bar)