®SULLAIR®
INDUSTRIAL AIR COMPRESSOR
1100E, 1500E, 1800E,
1100EV, 1500EV, 1800EV
11, 15 & 18KW/15, 20 & 25HP
Air-Cooled Standard & 24 KT
02250155_844_Cvr
PART NUMBER:
02250155–844
KEEP FOR
FUTURE
REFERENCE
©
SULLAIR CORPORATION
The information in this document is
correct at the time of printing for utility
compressor serial number
20060601XXXX
and all subsequent serial numbers.
OPERATORS MANUAL AND PARTS LIST

Table of Contents

Other manuals for Sullair 1109e

Questions and Answers

  • M
    Monica MooreAug 8, 2025
    Why is my Sullair 1109e Air Compressor not building full discharge pressure?
    • C
      Curtis WadeAug 8, 2025
      If your Sullair Air Compressor isn't building full discharge pressure, consider these potential causes: The air demand might be too great, so check service lines for leaks or open valves. The air filter might be dirty, so inspect the filter indicator and replace the element if needed. A plugged inlet valve bleed orifice could also be the problem, so ensure the control line bleed orifice is not blocked. Additionally, the pressure regulator might be out of adjustment or defective, so adjust it or replace the diaphragm if necessary. Finally, a defective unload solenoid valve could be the issue, so check that it closes when energized, and replace it if defective.
  • M
    Monica EnglishAug 17, 2025
    Why won't my Sullair 1109e start?
    • A
      Alexander CallahanAug 17, 2025
      If your Sullair Air Compressor won't start, several factors could be the cause. First, check that the main disconnect switch is closed. Another possible cause is a blown line fuse, which would need to be replaced. Also, the motor starter overload might have tripped; try resetting it, and if the issue continues, inspect the motor starter contacts. Finally, low incoming line voltage could be the culprit, so check the voltage and consult your power company if it's too low.
  • G
    Garrett ClarkNov 27, 2025
    What to do if my Sullair 1109e Air Compressor shuts down with air demand present?
    • S
      sandra81Nov 27, 2025
      If your Sullair Air Compressor shuts down while there's still air demand, there are several potential reasons. It could be due to a loss of control voltage; try resetting it, and if the problem continues, ensure the line pressure doesn't exceed the compressor's maximum operating pressure. Low incoming voltage can also cause this issue, so consult your power company. Other possibilities include the separator needing maintenance (check the indicator under full load), a high pressure setting in the WS controller (reset it), a defective unload solenoid valve (repair if defective), or a defective blowdown valve (repair if defective). Restricted cooling air flow (clean the cooler and check ventilation), high ambient temperature (improve ventilation), low fluid level (add fluid), or a malfunction...

Summary

1 - SAFETY

1.1 GENERAL

General safety information for operating Sullair compressors.

1.2 PERSONAL PROTECTIVE EQUIPMENT

Required PPE for operating and maintaining the compressor.

1.3 PRESSURE RELEASE

Procedures for safely releasing system pressure.

1.4 FIRE AND EXPLOSION

Safety precautions regarding fire and explosion hazards.

1.5 MOVING PARTS

Safety guidelines for avoiding hazards from moving parts.

1.6 HOT SURFACES, SHARP EDGES AND SHARP CORNERS

Precautions for hot surfaces, sharp edges, and corners.

1.7 TOXIC AND IRRITATING SUBSTANCES

Safety regarding toxic and irritating substances, including air quality.

1.8 ELECTRICAL SHOCK

Safety measures to prevent electrical shock.

1.9 LIFTING

Safe procedures for lifting and handling the compressor.

1.10 ENTRAPMENT

Safety precautions for preventing entrapment within the enclosure.

2 - DESCRIPTION

2.3 SULLAIR COMPRESSOR UNIT, FUNCTIONAL DESCRIPTION

Explains the function of the Sullair rotary screw compressor unit.

2.6 CONTROL SYSTEM, FUNCTIONAL DESCRIPTION

Details the compressor's control system and operating modes.

3 - SPECIFICATIONS

3.1 TABLE OF SPECIFICATIONS

Lists technical specifications for various compressor models.

Section 6 MAINTENANCE

6.9 TROUBLESHOOTING GUIDE

Guide to diagnose and resolve common compressor symptoms.

Section 7 PARTS LISTS

7.11 CONTROL SYSTEM AND ELECTRIC PARTS

Illustrated parts list for control system and electrical components.

Sullair 1109e Specifications

General IconGeneral
Model1109e
TypeRotary Screw Air Compressor
Operating Pressure100 PSIG
Weight6, 500 lbs
Phase3
Voltage460 V

Related product manuals