SECTION 3 1100E, 1500E, 1800E USER MANUAL
27
3.5 IDENTIFICATION, AIR-COOLED
NOTES:
1. Allow 4.00 ft. (1.25 meters) minimum clearance around
machine for access and free circulation of air.
2. A foundation or mounting capable of supporting the weight of
package, and rigid enough to maintain the compressor frame
level is required. The compressor frame must be leveled and
secured between the frame and the foundation. No piping loads
must be permitted at external connections.
3. All dimensions are ± 1/2" (12. 7mm).
4. Recommended incoming customer power supply is shown on
drawing.
5. If ductwork is to be installed for cooling air, high static fan must
be selected. Maximum allowable additional static pressure 0.4
in H2O with high static fan.
Main Motor HP Motor Type Weight CFM Cooling Air
15 TEFC 1044 LBS/474 KG 2000 CFM
20 TEFC 1098 LBS/498 KG 2000 CFM
25 TEFC 1122 LBS/509 KG 2000 CFM