SECTION 3 1800-3000 USER MANUAL
31
3.6 AIR-COOLED, IDENTIFICATION 40HP
Main Motor HP Motor Type Weight CFM Cooling Air
40 ODP 1556 LBS/706 KG 2900 CFM
40 TEFC 1613 LBS/732 KG 2900 CFM
NOTES:
1. ALLOW 4.00 FT. [1.25 METERS] MINIMUM CLEARANCE
AROUND MACHINE FOR ACCESS AND FREE CIRCULA-
TION OF AIR.
2. A FOUNDATION OR MOUNTING CAPABLE OF SUPPORT-
ING THE WEIGHT OF PACKAGE, AND RIGID ENOUGH TO
MAINTAIN THE COMPRESSOR FRAME LEVEL IS
REQUIRED. THE COMPRESSOR FRAME MUST BE LEV-
ELLED AND SECURED BETWEEN THE FRAME AND THE
FOUNDATION. NO PIPING LOADS MUST BE PERMITTED
AT EXTERNAL CONNECTIONS.
3. ALL DIMENSIONS ARE ±1/2" [12.7MM].
4. RECOMMENDED INCOMING CUSTOMER POWER SUP-
PLY IS SHOWN ON DRAWING.
5. IF DUCTWORK IS TO BE INSTALLED FOR COOLING AIR,
HIGH STATIC FAN MUST BE SELECTED. MAX ALLOW-
ABLE ADDITIONAL STATIC PRESSURE 0.4 IN H20 WITH
HIGH STATIC FAN.
A1: SPACE REQUIRED TO OPEN DOORS
A2: SPACE REQUIRED TO OPEN STARTER PANEL
A3: CONTROLLER
A4: E-STOP
A5: AIR INLET
A6: EXHAUST AIR OUT
A7: CONTAINMENT PAN DRAIN
A8: INCOMING CUSTOMER POWER SUPPLY
Ø2.50[63.5]
A9: MOISTURE DRAIN CONNECTION 1/4"-18 NPT
A10: AIR OUT CONNECTION 1-1/2" NPT