SECTION 3
®SULLAIR®
16
3700 Operator’s Manual and Parts List
COMPRESSOR: STANDARD MODELS:
Type: Rotary Screw
Standard Operating Pressure (II): 100 psig (07 bar)
125 psig (09 bar)
150 psig (10 bar)
175 psig (12 bar)
Bearing Type: Anti-friction
Ambient Temperature (Max.) (III): 104°F (40°C)
Cooling: Pressurized fluid
Compressor Fluid: Sullair Sullube
Sump Capacity: 3.0 gallons (11.4 liters)
Control: Microprocessor controller
(II) Special compressors are available for operation at higher pressures.
(Ill) Special compressors are available for operation in higher ambient temperature.
MOTOR (IV): STANDARD MODELS:
Size: 40, 50, 60 HP / 30, 37, 45 KW
Type: C-Flanged, Open Dripproof, Epact Efficiency, Three
Phase, 230/460 Hz, 380-415 (400) 50 Hz
Maximum Ambient Temperature 104°F (40°C)
Options Available: 200V and 575V 60 Hz, 220 50 Hz
TEFC also available: CE Approved
Starter: Full Voltage Magnetic, Wye-Delta or Solid State
Options Available: VSD Optional, 460V, 575V, 400V 50 Hz
Speed - 40, 50, 60 HP: 1765 RPM (60 Hz) or 1475 RPM (50 Hz)
(IV) Multi-frequency and voltage motors are used. The compressors must be used only with the specified electrical
frequency and voltage.
NOTE
For latest sound test data, consult Sullair
Factory.
SU_0000040