Section 4
 69
600H, 700HH, 750, 750H, 750HH, 825, 900H, 1050 USER MANUAL
OPERATION
4.1 GENERAL
While Sullair has built into this compressor a
comprehensive array of controls and indicators to
assure you that it is operating properly, you will want
to recognize and interpret the readings which will call
for service or indicate the beginning of a malfunction.
Before starting your Sullair compressor, read this
section thoroughly and familiarize yourself with the
controls and indicators—their purpose, location and
use
.
4.2 PURPOSE OF CONTROLS
CONTROL OR INDICATOR PURPOSE
Power ON Switch (Start Up) * The engine switch is used to both energize the compressor’s electrical 
system and engage the engine/starter. It also has a built-in anti-restart 
device that protects the starter from engaging while the engine is 
running. The switch must be turned back to the “off” position before the 
engine can be re-started.
Voltmeter * Monitors the condition of the batteries and the charging circuit. The 
normal reading is 24 to 48 volts.
Service Air Pressure Gauge * Continually monitors the pressure inside the receiver tank at various 
load and unload conditions.
Engine Temperature Gauge * Monitors the temperature of the engine water. The normal operating 
temperature should read approximately 160ºF to 210ºF (71ºC to 99ºC).
Controller * Depicts system related diagnostics. Can be used for system 
performance monitoring.
Compressor Temperature Gauge * Monitors the temperature of the air/fluid mixture leaving the compressor 
unit. The normal reading should be approximately 210ºF to 250ºF 
(99ºC to 121ºC).
System Pressure Sensor Prevents starter engagement when the air system is pressurized.
Fluid Level Sight Glass Monitors the fluid level in the receiver tank. Proper level is always 
visible in the sight glass. Check the level when the compressor is 
shutdown.
Receiver Tank Temperature Switch Opens the electrical circuit to shut down the compressor when then 
receiver tank temperature reaches 250ºF (121ºC).
 NOTE
When restarting the compressor, the controller will 
not allow restart until system pressure falls below 
10 psig (0.7 bar) or less. More than 10 psig (0.7 
bar) can put extra load on the starter.