Minimal installation requirements:
Select a room which is dry, free from dust, and protected from atmospheric disturbances.
The supporting area must be smooth, level, and able to hold the weight of the dryer.
Minimum ambient temperature +1 ºC.
Maximum ambient temperature +50 ºC.
Allow at least a clearance of 1 m on each side of the dryer to facilitate possible maintenance
operations.
Installation of the dryer does not require the dryer being anchored to the mounting surface but
may be by local codes for safety reasons.
INSTALLATION LAYOUT
1
Air Compressor
2
Final After Cooler
3
Condensate separator
4
Filter 5 micron
5
Air Receiver
6
Filter 1 micron
7
Adsorption Dryer
8
Dried Air Outlet
9
Condensates drain
Dryer is supplied with 0.01-micron filter on the inlet and a 1-micron filter on the
outlet. It is recommended to install both 5 micron and 1-micron filter before the
dryer, to protect the life of the inlet filter.
Type A installation is suggested when the compressed air treated from the dryer is only a
part of the total flow rate of the compressor; or when the compressor operates at reduced
intermittence and the total consumption equals the compressor flow rate.