DHL Regenerative Dryer w/SHDC-2300 touch screen controller User Manual US-EN
28
(Figure 5.9A) Dew point trend intial start
The red line will represent the right-side tower and the blue line will represent the left side tower.
The Y-axis of the graph is scaled to the dew point probe's operating scale. The default scale will be
(-112 to +68. ) This scale is set at the factory in the Dew Point Sensor Setup screen and should not be
changed. The graphing dew point sampling can be set from 1 hour up to 24 hours and can be cleared in the
OE Setup screen.
Pressing the Zoom button will change the view of the graph by zooming in on the Y-axis scale to -30
through +30. The Zoom is a one step process,the Zoom Button will disappear and a Back button will
appear. Pressing the Back button will take the view back to the full scale. (Figure 5.9B)
(Figure 5.9C) Dew point trend
5.9B

Other manuals for Sullair DHL-80