Stage 2: 
 
●  The left tower purge solenoid valve is closed and the left tower is re-pressurized to line 
pressure. Once it is re-pressurized, the left tower is ready to start the drying process. 
 
 
Stage 3: 
 
●  The left tower inlet valve is opened and it starts to dry the wet compressed air. The right 
tower inlet valve is closed and the right tower purge valve is opened. This process 
depressurizes the right tower. Now, as the dry air exits the left tower, a small portion of this 
dry air (termed “Purge Air”) is redirected towards the right tower (flow controlled by the 
repressurization valve). This compressed purge air expands to near atmospheric pressure 
in the right tower, thereby increasing its moisture absorbing capacity. As this expanded dry 
air flows through the right tower, it absorbs the H2O from the desiccant bed, exhausting it 
through the exhaust muffler. At the end of this stage, the right tower desiccant bed will have 
completely regenerated (i.e. completely free of moisture) and is ready for adsorbing 
moisture from the incoming wet compressed air.  
 
 
Stage 4: 
●  The right tower purge solenoid valve is closed and the right tower is re-pressurized to line 
pressure. Once it is re-pressurized, the right tower is ready to start the drying process. 
 
This process is termed as one cycle and it continues automatically without any need for user 
intervention. 
 
PLEASE NOTE: The left and right of the dryer is from the perspective of the operator standing in 
front of the dryer (the controller side) 
 
PLEASE NOTE: The desiccant material, if contaminated from lubricant oil, loses its absorption 
property. Moreover during operation, the desiccant can release solid particles (powders) 
particularly abrasive and extremely damaging for the final users. 
 
 
●  For this reason the dryer is equipped with two high efficiency filters: 
 
-  Inlet filter, 0.01 micron filtration grade, with differential gauge and electronic timer drain or 
optional zero loss drain. 
-  Outlet filter, 1 micron filtration grade, with differential gauge and manual drain.