Minimal installation requirements:
● Select a room which is dry, free from dust, and protected from atmospheric disturbances.
● The supporting area must be smooth, level, and able to hold the weight of the dryer.
● Minimum ambient temperature +1 ºC.
● Maximum ambient temperature +50 ºC.
● Allow at least a clearance of 1 m on each side of the dryer to facilitate possible maintenance
operations.
● Installation of the dryer does not require the dryer being anchored to the mounting surface but
may be by local codes for safety reasons.
Dryer is supplied with 0.01-micron filter on the inlet and a 1-micron filter on the
outlet. It is recommended to install both 5 micron and 1-micron filter before the
dryer, to protect the life of the inlet filter.
● Type A installation is suggested when the compressed air treated from the dryer is only a
part of the total flow rate of the compressor; or when the compressor operates at reduced
intermittence and the total consumption equals the compressor flow rate.