SECTION 4 MAINTENANCE
* Advice
In order to ensure continuous and trouble-free operation, a
maintenance contract with
S
S
u
u
l
l
l
l
a
a
i
i
r
r
®
®
is recommended.
Also, the following points should be checked regularly:
Daily
Carry out a general visual check and watch out for possible disturbances
during operation.
Check function by manually operating the automatic condensate drain on
the pre-filter.
Do an optical color test on the blue gel indicator for non-DDS dryers:
Indicator Color Approx. dew point [ °C]
Blue gel
Blue
Pink
Transparent
- 25
0
+ 15
Weekly
Check the differential pressure on the pre-filter, which should not exceed
10 PSID. Values greater than this indicate that the filter cartridge must be
changed.
Check the differential pressure on the after-filter, which should not exceed
10 PSID. Values greater than this indicate that the filter cartridge must be
changed.
Check the backpressure at the silencer placed behind the exhaust valve
combination; it should not exceed 5 PSIG. Use the gauge of the vessel
that is to be regenerated.
Drain inlet and exhaust valve chambers using valves provided below the
valve (refer to photo attached).
Drain pilot air filter housing of condensate (refer to photo attached).

Table of Contents