4: Installation ShopTek™ ST4, ST5, ST7, ST11, ST15 Three-phase 60 Hz User Manual
88292018-236 R00
34 Subject to EAR, ECCN EAR99 and related export control restrictions.
4.2 Ventilation and cooling
ShopTek compressors require a three foot (one
meter) clearance around their perimeter.
The location should be free from standing
water.
Clean air should be supplied to the compres-
sor, free from exhaust and paint fumes, dust,
metal particles, or caustic chemical vapors.
Hot exhaust air should be vented out of the
area to prevent its recirculation back into the
compressor’s cooling system.
Ducting or some other means must be used to
ensure that hot exhaust air is vented away from
the compressor if the compressor’s housing
has minimal overhead clearance.
Table 4-1: Ventilation requirements
Model
Ventilation air required
cfm m
3
/hr
ST4 612 1040
ST5 612 1040
ST7 612 1040
ST11 1471 2500
ST15 1471 2500
NOTE
Remove the red shipping straps/shipping studs
before operating the drive assembly. See Figure
4-1 and Figure 4-2.
NOTE
Housing the compressor in an inadequately ven-
tilated enclosure will cause higher compressor
operating temperatures.