EasyManua.ls Logo

Sullair ShopTek ST5 - 4000 Hr; 1 Year Maintenance; Annual Maintenance; Fluid Maintenance Guide; Fluid Filter Maintenance

Sullair ShopTek ST5
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6: Maintenance ShopTek™ ST4, ST5, ST7, ST11, ST15 Three-phase 60 Hz User Manual
88292018-236 R00
42 Subject to EAR, ECCN EAR99 and related export control restrictions.
6.3.3 Every 4000 hours of operation or one
year (whichever occurs first)
Replace the separator element. Refer to Section 6.7.
6.3.4 Every one year
Change the fluid. Refer to Section 6.4.
6.3.5 Every two years
Replace the hoses. Refer to Section 6.10.
6.4 Fluid maintenance
Drain the separator tube and change the compressor
fluid using instructions shown in Section 3.2: Lubrication
guide on
page 22.
6.5 Fluid filter maintenance
Refer to Figure 6-3. Replace the fluid filter under any of
the following conditions, or whichever occurs
first:
Every 2000 hours a display on the controller
ind
icates the need for replacement
Every fluid change.
6.5.1 Fluid filter replacement
Refer to Figure 6-3.
1. Use a strap wrench to remove the fluid filter
and gasket.
2. Dispose of the old filter according to applica-
ble federal, state and local regulations.
3. Clean gasket seating surface.
4. Apply a light film of fluid to the filter gasket of
a new fluid filter.
5. Hand tighten the filter until the gasket is seated.
6. Continue tightening filter an additional ½ to
¾ turn.
7. Replace any lost fluid. Do not overfill.
8. Restart compressor and check for leaks.
Figure 6-2: Return line strainer—ST11, ST15
1. Strainer
2. Separator tube
NOTE
Dispose of fluids in accordance with applicable
federal, state and local regulations.
Figure 6-3: Fluid filter assembly
1. Fluid filter
2. Fluid sample valve

Table of Contents

Related product manuals