33
・Refer to page 6 table 1-2 for brake type.
・This drawing shows for a motor based on standard specification for domestic market.Motor
based on overseas standard shall be referred to us.
Brake type : FB-01A1-02A1
100V 200V
Fig.32-a-2 For operating in one directions (In a case of capacitor start and capacitor-run type 0.1kW-0.4kW)
Nomal braking action
Fast braking action
Control panelTerminal box
Control panelTerminal box
Control panelTerminal box
Control panelTerminal box
Nomal braking action
Fast braking action
Control panelTerminal box
Control panelTerminal box
Control panelTerminal box
Control panelTerminal box
Use fast braking action for lifting devices or
for better stopping accuracy.
DC braking capacity (for DC coil loading)
exceeding 5 times the braking current shown
on the name plate is recommended for the
fast braking action.
Note : Connection to Z1 and Z2 shall be
exchanged with each other when
reverse rotation is necessary if the motor
is provided only for rotation in one
direction.
MC : Electromagnetic
contactor
OLR : Overload relay or
thermal relay
VR : Varistor (Protector
element)
These should be
furnished by the
customer.