H-6
8
8.2 Display of trip information
8.2.1 Trip code display
If the inverter trips, an error code is displayed to suggest the cause. Since trip records are retained, information
on each trip can be displayed anytime in the status monitor mode.
Display of trip information
Error code
Failure
code
Description
(*) 0000 No error

0001 Overcurrent during acceleration

0002 Overcurrent during deceleration

0003 Overcurrent during constant speed operation

0004 Load-side overcurrent during start-up

0005 Armature-side overcurrent during start-up

0008 Input phase failure or exhaustion of main circuit capacitor

0009 Output phase failure

000A Overvoltage during acceleration

000B Overvoltage during deceleration

000C Overvoltage during constant-speed operation

000D Inverter overload trip

000E Motor overload trip

000F Dynamic braking register overload trip

0010 Overheating trip or thermal detector failure
0011 Emergency stop

0012 E
2
PROM fault 1 (writing error)

0013
E
2
PROM fault 2 (initialization error) or power-off during the setting of


0014 E
2
PROM fault 3 (reading error)

0015 Inverter RAM fault

0016 Inverter ROM fault

0017 CPU fault trip 1

0018 Communication error

001A Current defector fault

001B Optional circuit board format error

001D Small-current trip

001E Undervoltage trip

0020 Over-torque trip

0022 Ground fault