10
Table of Parameters
Function
No. Name Range Def. *
1
Control Mode
V/f
SV
Carrier Frequency
C6-01 Drive Duty Selection 0,1 0 S S
C6-02 Carrier Frequency Selection 1 ~ B,F 2 S S
C6-03 Carrier Frequency Upper Limit 1.0 ~ 15.0
*4
C6-04 Carrier Frequency Lower Limit 1.0 ~ 15.0 ×
C6-05 Carrier Frequency Proportional Gain 00 ~ 99
×
Frequency Reference
d1-01 Frequency Reference 1
0.00 ~400.00 0.00Hz
S S
d1-02 Frequency Reference 2 S S
d1-03 Frequency Reference 3 S S
d1-04 Frequency Reference 4 S S
d1-05 Frequency Reference 5
d1-06 Frequency Reference 6
d1-07 Frequency Reference 7
d1-08 Frequency Reference 8
d1-09 Frequency Reference 9
d1-10 Frequency Reference 10
d1-11 Frequency Reference 11
d1-12 Frequency Reference 12
d1-13 Frequency Reference 13
d1-14 Frequency Reference 14
d1-15 Frequency Reference 15
d1-16 Frequency Reference 16
d1-17 Jog Frequency Reference
0.00 ~ 400.00
5.00 Hz S S
Freq.
Limits
d2-01 Frequency Reference Upper Limit 0.0 ~ 110.0 100.0%
d2-02 Frequency Reference Lower Limit 0.0 ~ 110.0 0.0%
d2-03 Master Speed Reference Lower Limit 0.0 ~ 110.0 0.0%
Jump
Frequency
d3-01 Jump Frequency 1 0.0 ~ 400.0 0.0 Hz
d3-02 Jump Frequency 2 0.0 ~ 400.0 0.0 Hz
d3-03 Jump Frequency 3 0.0 ~ 400.0 0.0 Hz
d3-04 Jump Frequency Width 0.0 ~ 20.0 1.0 Hz
Frequency Reference Hold
d4-01
Frequency Reference Hold Function
Selection
0,1 0
d4-03
Frequency Reference Bias Step
(Up/Down 2)
0.00 ~
99.99
0.00Hz
d4-04
Frequency Reference Bias Accel/Decel
(Up/Down 2)
0,1 0
d4-05
Frequency Reference Bias
Operation Mode Selection (Up/Down 2)
0,1 0
d4-06
Frequency Reference Bias (Up/Down 2)
-99.9 ~
+100.0
0.0%
d4-07
Analog Frequency Reference
Fluctuation Limit (Up/Down 2)
0.1 ~
+100.0
1.0%
d4-08
Frequency Reference Bias Upper Limit
(Up/Down 2)
0.0 ~ 100.0 100.0%
d4-09
Frequency Reference Bias Lower Limit
(Up/Down 2)
-99.9 ~
0.0
0.0%
d4-10
Up/Down Frequency Reference Limit
Selection
0,1 0
Offset
Freq.
d7-01 Offset Frequency 1 -100.0 ~ +100.0 0.0%
d7-02 Offset Frequency 2 -100.0 ~ +100.0 0.0%
d7-03 Offset Frequency 3 -100.0 ~ +100.0 0.0%
V/f Pattern Characteristics
E1-01*
2
Input Voltage Setting 155 ~ 255 *4 S S
E1-03 V/f Pattern Selection 0 ~ F F
E1-04 Maximum Output Frequency 40.0 ~ 400.0 60.0 Hz S S
E1-05*
2
Maximum Output Voltage 0.0 ~ 255.0 200.0 V S S
E1-06 Base Frequency 0.0 ~ E1-04 60.0 Hz S S
E1-07 Middle Output Frequency 0.0 ~ E1-04 3.0 Hz
E1-08 Middle Output Frequency Voltage 0.0 ~ 255.0 *4
Function
No. Name Range Def. *
1
Control Mode
V/f
SV
V/f Pattern
Characteristics
E1-09 Minimum Output Frequency 0.0 ~ E1-04 1.5 Hz S S
E1-10 Minimum Output Frequency Voltage 0.0 ~ 255.0 *4
E1-11 Middle Output Frequency 2 0.0 ~ E1-04 0.0 Hz
E1-12*
2
Middle Output Frequency Voltage 2 0.0 ~ 255.0 0.0 V
E1-13*
2
Base Voltage 0.0 ~ 255.0 0.0 V S
Motor Parameters
E2-01 Motor Rated Current
Rated Current
10 ~ 200%
*4
S S
E2-02 Motor Rated Slip 0.00 ~ 20.00
E2-03 Motor No-Load Current
0 ~ E2-01 below
E2-04 Number of Motor Poles 2 ~ 48 4pole
E2-05 Motor Line-to-Line Resistance 0.000 ~ 65.000
*4
E2-06 Motor Leakage Inductance 0.0 ~ 40.0
E2-07
Motor Iron-Core Saturation Coefficient 1
0.00 ~ 0.50 0.50 ×
E2-08
Motor Iron-Core Saturation Coefficient 2
E2-07 ~ 0.75 0.75 ×
E2-09 Motor Mechanical Loss 0.0 ~ 10.0 0.0% ×
E2-10
Motor Iron Loss for Torque
Compensation
0 ~ 65535
*4
×
E2-11 Motor Rated Output 0.00 ~ 650.00 S S
E2-12
Motor Iron-Core Saturation Coefficient 3
1.30 ~ 5.00 1.30 ×
Motor 2 V/f Characteristics
E3-01 Motor 2 Control Method 0,2 0
E3-04 Motor 2 Max Output Frequency 40.0 ~ 400.0 60.0 Hz
E3-05*
2
Motor 2 Max Voltage 0.0 ~ 255.0 200.0 V
E3-06 Motor 2 Base Frequency 0.0 ~ E3-04 60.0 Hz
E3-07 Motor 2 Mid Output Freq. 0.0 ~ E3-04 3.0 Hz
E3-08*
3
Motor 2 Mid Output Freq. Voltage 0.0 ~ 255.0
13.6 V
(26.6 V)
E3-09 Motor 2 Min. Output Freq. 0.0 ~ E3-04 1.5 Hz
E3-10*
3
Motor 2 Min. Output Freq. Voltage 0.0 ~ 255.0
9.1 V
(17.7V)
E3-11 Motor 2 Mid Output Frequency 2 0.0 ~ E3-04 0.0 Hz
E3-12*
2
Motor 2 Mid Output Frequency Voltage 2
0.0 ~ 255.0 0.0 V
E3-13*
2
Motor 2 Base Voltage 0.0 ~ 255.0 0.0 V S
Motor 2 Parameters
E4-01 Motor 2 Rated Current
Rated Current
10 ~ 200%
*4
E4-02 Motor 2 Rated Slip 0.00 ~ 20.00
E4-03 Motor 2 Rated No- Load Current
0 ~ E4-01 below
E4-04 Motor 2 Motor Poles 2 ~ 48 4pole
E4-05 Motor 2 Line-to- Line Resistance 0.000 ~ 65.000
*4
E4-06 Motor 2 Leakage Inductance 0.0 ~ 40.0
E4-07
Motor 2 Motor Iron-Core Saturation
Coefficient 1
0.00 ~ 0.50 0.50 ×
E4-08
Motor 2 Motor Iron-Core Saturation
Coefficient 2
Setting of
E4-07 ~ 0.75
0.75 ×
E4-09 Motor 2 Mechanical Loss 0.0 ~ 10.0 0.0 ×
E4-10 Motor 2 Iron Loss 0 ~ 65535
*4
×
E4-11 Motor 2 Rated Capacity 0.00 ~ 650.00
×
E4-12
Motor 2 Iron-Core Saturation
Coefficient 3
1.30 ~ 5.00 1.30 ×
E4-14 Motor 2 Slip Compensation Gain 0.0 ~ 2.5 0.0
E4-15 Torque Compensation Gain Motor 2 0.00 ~ 2.50 1.00
E5-39 Current Detection Delay Time -1000 to 1000 0µs
PG Setup Parameters
F1-02
Operation Selection at PG Open
Circuit (PGo)
0 ~ 3 1
×
F1-03
Operation Selection at Overspeed (oS)
0 ~ 3 1 ×
F1-04 Operation Selection at Deviation 0 ~ 3 3
×
F1-08 Overspeed Detection Level 0 ~ 120 115%
×
F1-09 Overspeed Detection Delay Time 0.0 ~ 2.0 1.0
×
*1 : Default setting is determined by A1-02, Control Method Selection.
*2 : Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
*3 : Values shown here are for 200 V class drives. ( ) the value when using a 400 V class drive.
*4 : Default setting value is dependent on parameter o2-04, Drive Model Selection.