11
Function
No. Name Range Def. *
1
Control Mode
V/f
SV
PG Setup
Parameters
F1-10
Excessive Speed Deviation Detection Level
0 ~ 50 10% ×
F1-11
Excessive Speed Deviation
Detection Delay Time
0.0 ~ 10.0 0.5 s
×
F1-14 PG Open-Circuit Detection Time 0.0 ~ 10.0 2.0 s
×
Serial Communications Option Card
F6-01
Communications Error Operation Selection
0 ~ 3 1
F6-02
External Fault from Comm. Option Selection
0,1 0
F6-03
External Fault from Comm. Option
Operation Selection
0 ~ 3 1
F6-04 Bus Error Detection Time 0.0 ~ 5.0 2.0 s
F6-07 NetRef/ComRef Function Selection 0,1 0
F6-08 Reset Communication Parameters 0,1 0
F6-10 CC-Link Node Address 0 ~ 64 0
F6-11 CC-Link Communications Speed 0 ~ 4 0
F6-14 BUS Error Auto Reset 0,1 0
F6-50 DeviceNet MAC Address 0 ~ 64 0
F6-51 Device Net Communications Speed 0 ~ 4 0
F6-52 DeviceNet PCA setting 0 ~ 255 21
F6-53 DeviceNet PPA setting 0 ~ 255 71
F6-54
54 DeviceNet Idle Mode Fault Detection
0,1 0
F6-55 DeviceNet Baud Rate Monitor
0 ~ 2
(Read only)
-
F6-56 DeviceNet Speed Scaling Factor -15 ~ 15 0
F6-57 DeviceNet Current Scaling Factor -15 ~ 15 0
F6-58 DeviceNet Torque Scaling Factor -15 ~ 15 0
F6-59 DeviceNet Power Scaling Factor -15 ~ 15 0
F6-60 DeviceNet Voltage Scaling Factor -15 ~ 15 0
F6-61 DeviceNet Time Scaling Factor -15 ~ 15 0
F6-62 DeviceNet Heartbeat Interval 0 ~ 10 0
F6-63 MAC ID Memory
0 ~ 63
(Read only)
-
Multi-Function Digital Input
H1-01
Multi-Function Digital Input Terminal
S1 Function Selection
1 ~ 9F
40
H1-02
Multi-Function Digital Input Terminal
S2 Function Selection
41
H1-03
Multi-Function Digital Input Terminal
S3 Function Selection
0 ~ 9F
24
H1-04
Multi-Function Digital Input Terminal
S4 Function Selection
14
H1-05
Multi-Function Digital Input Terminal
S5 Function Selection
3(0)
H1-06
Multi-Function Digital Input Terminal
S6 Function Selection
4(3)
H1-07
Multi-Function Digital Input Terminal
S7 Function Selection
6(4)
Multi-Function Digital
Outputs
H2-01
Terminal MA, MB and MC
Function Selection (relay)
0 ~ 192
E
H2-02
Terminal P1 Function Selection
(open- collector)
0
H2-03
Terminal P2 Function Selection
(open- collector)
2
H2-06 Watt Hour Output Unit Selection 0 ~ 4 0
Analog Inputs
H3-01 Terminal A1 Signal Level Selection 0,1 0
H3-02 Terminal A1 Function Selection 0 ~ 41 0
H3-03 Terminal A1 Gain Setting -999.9 ~999.9 100.0%
H3-04 Terminal A1 Bias Setting -999.9 ~999.9 0.0%
H3-09 Terminal A2 Signal Level Selection 0 ~ 3 2
H3-10 Terminal A2 Function Selection 0 ~ 41 0
H3-11 Terminal A2 Gain Setting -999.9 ~ 999.9 100.0%
H3-12 Terminal A2 Bias Setting -999.9 ~ 999.9 0.0%
H3-13 Analog Input Filter Time Constant 0.00 ~ 2.00 0.03 s
H3-14
Analog Input Terminal Enable Selection
1,2,7 7
Function
No. Name Range Def. *
1
Control Mode
V/f
SV
Analog
Inputs
H3-16 Terminal A1 Offset -500 ~ 500 0
H3-17 Terminal A2 Offset -500 ~ 500 0
Multi-Function
Analog Outputs
H4-01
Multi-Function Analog Output Terminal AM
000 ~ 999 102
H4-02
Multi-Function Analog Output
Terminal AM Gain
-999.9 ~999.9 100.0% S S
H4-03
Multi-Function Analog Output
Terminal AM Bias
-999.9 ~999.9 0.0%
MEMOBUS/Modbus Communications
H5-01 Drive Node Address 0 ~ FFH 1F
H5-02 Communication Speed Selection 0 ~ 8 3
H5-03 Communication Parity Selection 0 ~ 2 0
H5-04
Stopping Method After
Communication Error
0 ~ 3 3
H5-05
Communication Fault Detection Selection
0,1 1
H5-06 Drive Transmit Wait Time 5 ~ 65 5 ms
H5-07 RTS Control Selection 0,1 1
H5-09 CE Detection Time 0.0 ~ 10.0 2.0 s
H5-10
Unit Selection for MEMOBUS/Modbus
Register 0025H
0,1 0
H5-11
Communications ENTER Function Selection
0,1 1
H5-12 Run Command Method Selection 0,1 0
Pulse Train Input/Output
H6-01
Pulse Train Input Terminal
RP Function Selection
0 ~ 3 0
H6-02 Pulse Train Input Scaling 100 ~ 32000 1440 Hz
H6-03 Pulse Train Input Gain 0.0 ~ 1000.0 100.0%
H6-04 Pulse Train Input Bias -100.0 ~+100.0 0.0%
H6-05 Pulse Train Input Filter Time 0.00 ~ 2.00 0.10 s
H6-06
Pulse Train Monitor Terminal MP
Selection
000,031,101,102,
105,116,501,502
102
H6-07 Pulse Train Monitor Scaling 0 ~ 32000 1440 Hz
H6-08 Pulse Train Min. Frequency 0.1 ~ 1000.0 0.5 Hz
Momentary Power Loss
L1-01 Motor Overload Protection Selection 0 ~ 2,6 1 S S
L1-02 Motor Overload Protection Time 0.1 ~ 5.0 1.0 min
L1-03
Motor Overheat Alarm Operation
Selection (PTC input)
0 ~ 3 3
L1-04
Motor Overheat Fault Operation
Selection (PTC input)
0 ~ 2 1
L1-05
Motor Temperature Input Filter Time
(PTC input)
0.00 ~ 10.00 0.20 s
L1-08 Electrothermal Level Setting 1
. A
10~150%
*4
L1-09 Electrothermal Level Setting 2
L1-13
Continuous Electrothermal Operation Selection
0,1 1
L1-22*
2
Leakage Current Filter Time Constant 1
0.0 ~ 60.0 20.0S
L1-23*
2
Leakage Current Filter Time Constant 2
0.0 ~ 60.0 1.0S
Stall Prevention Function
L2-01
Momentary Power Loss Operation Selection
0 ~ 2 0
L2-02
Momentary Power Loss Ride-Thru Time
0.0 ~ 25.5
*4
L2-03
Momentary Power Loss Minimum
Baseblock Time
0.1 ~ 5.0
L2-04
Momentary Power Loss Voltage
Recovery Ramp Time
0.0 ~ 5.0
L2-05*
3
Undervoltage Detection Level (Uv) 150 ~ 210
L2-06 KEB Deceleration Time 0.0 ~ 200.0 0.0s
L2-07 KEB Acceleration Time 0.0 ~ 25.5 0.0s
L2-08
KEB Start Output Frequency Reduction
0 ~ 300 100%
L2-11*
3
Desired DC Bus Voltage during KEB 150 ~ 400
E1-01×
1.22(V)
Stall Prevention
Function
L3-01
Stall Prevention Selection during Acceleration
0 ~ 2 1
L3-02
Stall Prevention Level during Acceleration
0 ~ 150 *4
L3-03
Stall Prevention Limit during Acceleration
0 ~ 100 50%
L3-04
Stall Prevention Selection during Deceleration
0 ~ 4,7 0 S S
L3-05 Stall Prevention Selection during Run 0 ~ 2 1
×
L3-06 Stall Prevention Level during Run 30 ~ 150 *4
×
*1 : Default setting is determined by A1-02, Control Method Selection.
*2 : Parameter can be changed and displayed at parameter C6-02=B.
*3 : Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
*4 : Default setting value is dependent on parameter o2-04, Drive Model Selection.
Table of Parameters