EasyManua.ls Logo

Sumitomo PARAMAX 9000 Series - Parallel Shaft Fan Installation Method

Sumitomo PARAMAX 9000 Series
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
4-3) Installation method for PARAMAX with fan (Parallel shaft)
Be careful for injuries with sharp edges of keyways and parts.
Keep accessories together to prevent losing during installation.
Handle parts carefully to prevent damage. Avoid water and dust.
Table 10 Bolt tightening torques
Reducer installation procedure
(1) Remove bolt 1. 2. , and fan hood 3. (Fig.4).
If there is no enough space to tighten the bolt 9. ,
If the fan hood 5. and fan rotor 7. are removed,
(a) Remove bolt 4. , and fan hood 5. (fig.5).
(b) Remove bolt 6. , and fan rotor 7. (Fig.6).
(3) Install fan hood 3. to the reducer with bolt 1. 2. (Fig.4).
See table 10 for bolt tightening torque of bolt 1. , 2. , 4. , and 6. .
(c) Install fan rotor 7. to the fan hub 8. with bolt 6. .
(d) Install fan hood 5. to the reducer with bolt 4. (Fig.5).
(2) Install reducer to the installation surface with bolt 9. (fig.7).
Torque tolerance: 10%
Bolt
Bolt 1. ,2. ,4. Bolt 6.
Tightening torque
N
.
m
M6
M8
M10
M12
10.8
11.3
39.2
97.4
Fig.5
Fan hood 5. Bolt 4.
Fig.4
Fan hood 3.Bolt 1.
Bolt 2.
Fig.7
Fan hub 8. Bolt 9.
Fig.6
Bolt 6. Fan rotor 7.
COMMON
CAUTION
Bolt
Bolt 1. ,2. ,4. Bolt 6.
Tightening torque
N
.
m
M20
M24
M30
M36
328
190
652
1140
!