3
List of Functions
List of Functions
Monitor Mode/Basic Setting Mode
Expanded Function A (Frequently Used Functions)
Initial setting
Monitor/setting RangeFunctionCodeSF
SF
HF
HF
MonitorSetting
Expanded
Function
Basic setting
Analog input
setting
Multispeed freg setting
V/F
characteristics
●●d01 Output frequency monitor 0.0360.0Hz
●●d02 Output current monitor 0.00999.9A
●●d03 Running direction monitor F(forward run), r(reverse run), (stop)
●●d04 PID feedback value monitor 0.019,999
●●d05 Input terminal status monitor Display the status of terminal
●●d06 Output terminal status monitor Display the status of terminal
●●d07
Operating frequency converted value monitor
(output frequency (Hz))×(frequency converted value: b86)
●●d08 Trip monitor Details of the latest error are displayed
●●d09 Trip history monitor
The causes of past two errors, excluding the latest one, are displayed
●●F01 Output frequency setting 0.5360Hz
Volume set value
●●F02 Acceleration time 1 setting 0.13000s 10.0s
●●F03 Deceleration time 1 setting 0.13000s 10.0s
●●F04 Running direction setting Forward/Reverse Forward
●●A-- (Extended function of A group setting)
●●B-- (Extended function of B group setting)
●●C-- (Extended function of C group setting)
H-- (Extended function of H group setting)
00: Potentiometer(Front case)
●●A01 Frequency Command 01: Control terminal 00
02: Panel or Digital operator
01: Control terminal
02: Panel or Digital operator
●●A03 Base frequency setting 50360Hz 60Hz
●●A04 Maximum frequency setting 50360Hz 60Hz
●●A11 External frequency setting start 0.0360Hz 0.0Hz
●●A12 External frequency setting end 0.0360Hz 0.0Hz
●●A13 External frequency setting start rate 0100% 0%
●●A14 External frequency setting end rate 0100% 100%
00: Set frequency of (A11)
01: 0Hz
●●A16
External frequency sampling count setting
18 times 8
0: 0Hz
1: 5Hz
2: 10Hz
3: 15Hz
4: 20Hz
5: 30Hz
6: 40Hz
7: 50Hz
8: 60Hz
Other: 0Hz
●●A38 Jogging frequency setting 0.009.99Hz 1.0Hz
00: Free run stop
●●A39 Jogging stop operation selection 01: Decelerate stop 00
02: DC braking
00: Manual
01: Auto
●●A42 Manual torque boost setting 099 30
●●A43 Boost frequency setting 0.050.0% 1.5%
00: Constant torque 01: Reduced torque
02: Sensorless vector (HF only)
●●A45 Output voltage gain setting 50100% 100%
Initial setting
Monitor/setting RangeFunctionCode
●●
A02 Run command
●●
●●
A15
External frequency start pattern setting
A41 Torque boost mode selection
A44 V/F characteristics setting
●●
A20
|
A35
Multispeed frequency setting
(speed 0speed 15)
Setting range: 0.0360Hz
Arbitrary setting is possible
02
01
00
00