dia.
dia.85
Unit VR07
The CT directly detects the current of the secondary side of the inverter.
Table of combination of AC ammeter (ACF-12N) and current transformer
0-100%; 50divisions (X525AA048)
Construction of current transformer (CT) COMA-15 type: Totally molded current transformer with primary winding
COM-15-26 type: Totally molded current transformer, throughhole type
COM-15-30 type: Totally molded current transformer, throughhole type
Install the current transformer (CT) on the output side of the inverter.
Motor
capacity
(kW)
Part No. Part No.
Rated
current
[A]
Rated
current
[A]
Max.
scale
[A]
Max.
scale
[A]
Type Type
Meter MeterCT CT
Number
of
primary
through
holes
Number
of
primary
through
holes
200V class 400V class
X525AA078 3 3 COMA-15 5/5A -
X525AA079 5 5 COMA-15 5/5A -
X525AA080 5 10 COMA-15 10/5A -
X525AA081 5 15 COMA-15 15/5A -
X525AA082 5 20 COMA-15 20/5A -
X525AA083 5 30 COMA-15 30/5A -
X525AA042 5 50 COMA-15-26 50/5A 3
X525AA042 5 50 COMA-15-26 50/5A 3
---- -
X525AA078 3 3 COMA-15 5/5A -
X525AA079 5 5 COMA-15 5/5A -
X525AA080 5 10 COMA-15 10/5A -
X525AA080 5 10 COMA-15 10/5A -
X525AA081 5 15 COMA-15 15/5A -
X525AA082 5 20 COMA-15 20/5A -
X525AA083 5 30 COMA-15 30/5A -
0.2
0.4
0.75
1.5
2.2
3.7
5.5
7.5
COMA-15 COM-15-26
ACF-12N