OWNER’S MANUAL
Note: If your pool heater does not operate for reasons other than those mentioned above, please contact
Consumer Assistance Center (see “Introduction”, p. 3) to obtain the proper authorization for the warranty
to apply.
Ask your electrician to verify your heat pump’s power supply by
checking over the L1 and L2 connections in the unit’s service box.
There is no display and the fan is not running,
but the compressor is running.
While your SUMMIT pool heater
is in the heating mode, a large
quantity of warm and humid air
passes over the
evaporator and causes con-
densation. It is normal to see
condensation dripping under
the heater.
To check if the water really is a
leak, you must stop the heater
and leave the pool pump running
for over 5 hours. If water is still
coming out of your heater after
this period, then call your dealer
for service.
There is water around the unit.
Heat loss is too much for the heater; cover your pool as often as
you can.
Evaporator restricted due to improper location (see “Location”,
p.6).
Evaporator is dirty.
Restricted water flow.
Clean it.
Adjust water flow.
The heater is running but desired water
temperature cannot be reached.
19