EasyManua.ls Logo

Sunbeam 9362 - Natural Gas Conversion

Sunbeam 9362
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
propane
bellows
2
1
CAUTION
Natural gas conversion must be performed only by a
natural gas provider or service company.
propane hose
gas valve
propane
bellows
Natural Gas
Conversion
1-877-387-3639 | Page 9
1. Unscrew and disconnect propane regulator from
gas valve counterclockwise using the torque wrench.
2. Unscrew and disconnect the bellows from propane
orifice counterclockwise using the wrench, then
disconnect the propane orifice from the inlet tube.
Propane orifice is identified with a red mark.
Hardware Used
Torque Wrench
Hardware Used
Wrench