INSTALLATION
Page4
17BREQUIREMENTFORAFLOORPROTECTOR
Ifyourheateristobeinstalledoncarpet,floorboardsoracombustiblesurface,thenaproperly
constructedfloorprotectormadefromatleast12mmofcompressedcementsheetMUSTbeplaced
undertheheater,conformingtotheminimumdimensionsbelow.Thefloorprotectormustbeplacedon
afirmlevelsurface,andprovideafirmlevelsurfacefortheheater.
FLOORPROTECTORMINIMUMDIME NSIONS
Dimension MinimumValue
Minimumwidth
940mm
Minimumdep t h
1060mm
Fromdo o r tofrontofprotector
500mm
Fromdo o r toeachedgeoffloor
protector
200mm
18BCLEARANCES
Itismandatorythattheheaterisinstalledsufficientlyclearofcombustiblematerial.Seethediagramand
tablebelowforminimumclearancesforbothparalleltothewallandcornerinstallationconfigurations.
WARNING:Failuretoobservetheseclearancesfromanycombustiblematerial(includingloose
firewood)mayresultinafire,thedamagefromwhichmaynotbeclaimableagainstinsurance.
Theseclearancesapplyonlywhereastandard“default”fluekitisused,consistingof
Withintheroominterior:150mmdiameteractiveflueand200mmdiametercoatedgalvanized
180°perforatedfrontwithsolidback
Transitionto:defaultdoubleskinnedceilingpenetrationkit,withceilingplate
INSTALLATIONCLEARANCES
torearwall tosidewall tocorner
Distancefromedgeoftopplate
150mm 400mm 75mm
