INSTALLATION
Page3
1BBeforeYouBegin
ThisheatermustbeinstalledaccordingtothelatestversionofAS/NZS2918,relevantbuildingandlocal
governmentregulations,usingtheclearancesandrequirementsoutlinedintheseinstructions.
NOTE:Youmayneedtoobtainlocalgovernmentapprovalpriortoinstallingawoodheater.
Yourwoodheatermustbeinstalledbyaqualifiedpersonwhoseworkconformswithlocalcouncil
regulations,Australianstandards&manufacturersrecommendations.Failuretodosowillvoidyour
warrantyandcouldpossiblyvoidanyhomeinsurance.
WARNING:APPLIANCESINSTALLEDINACCORDANCEWITHTHISSTANDARDSHALLCOMPLYWITH
THEREQUIREMENTSOFAS/NZS4013WHEREREQUIREDBYTHEREGULATORYAUTHORITY,I.E.THE
APPLIANCESHALLBEIDENTIFIABLEBYACOMPLIANCEPLATEWITHTHEMARKING‘TESTEDTO
AS/NZS4013’.
ANYMODIFICATIONOFTHEAPPLIANCETHATHASNOTBEENAPPROVEDINWRITNGBYTHE
TESTINGAUTHORITYISCONSIDEREDTOBEINBREACHOFTHEAPPROVALGRANTEDFOR
COMPLIANCEWITHAS/NZS4013.
15BPOSITIONINGYOURWOODHEATER
Ensuretheheatercanbepositionedoutofwalkwaysandsufficientlyfarfromfurnitureandcurtains,
whilestillobservingrequiredclearances.
Ensurealsothatwherethefluepenetrationoftheceilingisclearofjoistsandrafters.
16BFLUEREQUIREMENTS
YourSuncoheatermustbeinstalledwithanapproved“default”fluekitavailablefromyourretailer.You
mustnotmodifythekitinanywayormixcomponentsfromotherkits.
Oneofthemostimportantfactorsthatdeterminestheperformanceofyourheateristheheightofthe
flue.Afluethatisnothighenough,ordoesnotextendfarenoughabovenearbyairflowobstructions,will
notallowtheheatertodrawairproperly,andcombustionwillsufferasaresult.StandardAs2918
requiresthefollowingasaminimum:
Theactiveflue(theinnermostpipeforamultiskinnedflue)mustterminateatleast4.6metres
abovethebaseoftheheater.
Theactivefluemustterminateatleast1mfromaslopingroof,and1.5maboveaflatroof.
Thefluemustbehigherthananyairflowobstructionwithina3mradiusbyatleast1m.
Whereitisimpracticaltoextendtheflueaboveairflowobstructions(egtreesveryclosetotheroof)
thenanantidowndraftcowlisadvised.
Theflueshouldextendaboveanywindowofaneighbouringproperty
Ifperformanceproblemsremainafterthefluehasbeenextendedasrequired,consultyourdealerfor
furtheradvice.