When output source priority is Solar first or battery
first
,output source will switch to utility from battery when the
battery voltage below the preset value. Setting range:40~60V
When output source priority is Solar first or battery first,
output source will switch to battery from utility when the
battery voltage above the preset value. Range:40~60V
Switch to utility power when the battery SOC is less than this
setting
Switches to inverter output mode when SOC is greater than
this setting
Charging stops when the charging current is less than the set
value
Triggers an alarm when the battery SOC is less than the set
value
Stops discharging when the battery SOC is less than the set
value
Stops charging when the battery SOC is touch the set value
Select the the local grid standard
Select the inverter output frequency
When the “ off/on grid mode “is “On grid”,you can set the max on-grid power(less than
the inverter rated power)
On grid reactive power
setting
Set range:0.9 leading to 0.9 lagging
Normal connect power
ramp rate
Grid power function F-P
curve
It is able to adjust inverter output
power according to grid frequency.
Grid power function V-P
curve
It is used to adjust the inverter active power
according to the set grid voltage.