87
Parameters SG30KU SG36KU
DC fuse Integrated
Overvoltage protection
Type III surge arrester
(Optional Type II DIN rail surge arrester)
AC switch Optional
AC fuse Optional
System data
Max. efficiency 98.5%
CEC efficiency 98.0%
Isolation method Transformerless
Ingress protection rating NEMA4X
Night power consumption <1W
Operating ambient temperature range
-25...+60℃ (>45℃ derating)
-13…+140℉(>113℉ derating)
Allowable relative humidity range 0...100%, no condensing
Cooling method Smart forced air cooling
Max. operating altitude
4000m (>3000m derating)
13123ft(>9842ft derating)
Display Graphic LCD
Communication RS485
DC connection type Screw terminals
AC connection type Spring clamp terminal
Certification
cCSAus
Safety and EMC Standard
UL 1741, IEEE 1547, IEEE1547.1,CSA C22.2
107.1-01-2001,FCC Part 15 Sub-part B
Class B Limits
Mechanical Data
Dimensions (W×H×D)
622×880×250mm
25" × 34.6" × 9.8"
Mounting method Wall bracket or Floorbracket
Weight 65kg