EasyManuals Logo

Sungrow SH10RT Faq

Sungrow SH10RT
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© 2021 Sungrow. All rights reserved. Subject to change without notice. Version 1.1
Sungrow Deutschland GmbH | Balanstr. 59 | 81541 München | www.sungrowpower.com
3-phase Hybrids-FAQ
Replacement or expansion of residential energy
storage battery module
Applicable to: SBR HV Batteries
Scenario:
1. If the customer needs to add more battery modules (for example, add two
battery modules to an existing SBR096).
2. If one battery module is faulty and new battery module needs to be
replaced.
3. If two battery modules need to be removed.
Solution:
For scenarios 1 and 2, the battery modules in use need to be charged or discharged
to SOC of the new battery. New battery’s SOC can be estimated with knowing
manufacturing date and storage time. (see below table)

Other manuals for Sungrow SH10RT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SH10RT and is the answer not in the manual?

Sungrow SH10RT Specifications

General IconGeneral
ModelSH10RT
CategoryInverter
Rated Power10 kW
Max. DC Input Voltage1100 V
AC Output Voltage230 V
Max. Efficiency98.4%
IP RatingIP65
Max. DC Input Power15 kW
Start Voltage180 V
Number of MPPTs2
Max. Output Current16 A
Rated Grid Frequency50/60 Hz
THDi<3%
European Efficiency98%
Max. Charging/Discharging Power10 kW
Max. Charging/Discharging Current25 A
Operating Temperature Range-25°C to +60°C
Cooling MethodNatural Convection
AC Voltage Range180 V - 280 V
Power Factor0.8 leading to 0.8 lagging