2.0 INSTALLATION
2.1 Selecting a Location for the SunPower Inverter
In choosing a location for the SunPower Inverter, consideration should be given to the
following criteria:
The heat sink temperatures can exceed 158 degrees (70° C). The SunPower Inverter
must be installed so that the top of the unit will not be contacted by persons.
The SunPower Inverter is suitable for installation both indoors and outdoors and the
enclosure has been given a NEMA 3R rating. When the SunPower Inverter is installed
outdoors, it should be shielded from rain and direct sunlight, if possible.
The SunPower Inverter is designed to handle the temperature extremes of most
climates. The operating and non-operating ambient temperature range is from -25° C to
40° C.
The following clearances are recommended for proper placement of the SunPower
Inverter:
A minimum 36² clearance between the bottom of the inverter box and the
ground.
Visibility of the operating LED’s and display located at the top front of the inverter
box should also be considered.
If the SunPower Inverter is to be installed in an enclosed space, adequate ventilation
must be provided.