26
C. Fixing the position of the trimmer solenoid (ass’y)
(See Figure 46.)
a)
When the whole trimmer shake linkage ① is in up
position, that is, when it has come back to its
original position after finishing trimming, the
distance ④ between the lower part of the roller ②
and the equal point of the trimming cam ③ is about
0.8~1mm. Assuming that this distance ④ never
changes, adjust the position of solenoid bracket ⑦
horizontally, where the solenoid housing ⑥ is
attached, to make the solenoid stroke ⑤ 4 mm.
Then, tightly fasten with fixing screw ⑧.
b) After adjusting the solenoid stroke ⑤, manually
operate the solenoid shaft ⑨ towards the arrow
direction. See whether it returns to its original
position fast and smooth when released. If not,
proceed with horizontal adjustment of the
bracket ⑦.
(2) Adjustment of linking device for movable knife shaft and the trimmer driving part (See Figure 47.)
A. When the previously explained adjustment of trimmer driving part is complete, it is in its normal position where the
trimmer shake linkage ① has returned to its up position after trimming action.
B. First, loosen the fixing screw ② of the movable knife shaft (right), hold the initial assembling angle of the crank
(right) ③ to be about 15°, 30
' to the left from the perpendicular line ⒕ drawn to its center ⒔. To make sure that this
position is maintained, adjust the length of the ball joint linking bar ⑤ which comes assembled to trimmer shake
linkage ①. Also, adjust the fixing screw ② tightly.
(※ For the adjustment of the ball joint linking bar ⑤, turn the linking bar ⑤ after loosening the nuts (left) ⑥ and
(right) ⑦. ⑥ is left nut and ⑦ is the right nut.)
C. Then, loosen fixing screw ⑧ of the movable knife shaft crank (left), and in the same angle as the crank(right)’s lower
assembling angle ⑨, place the crank(left) ⑩. Tightly fasten the fixing bolt ⑪ to make sure this position holds.
D. When the linking device is connected as such, the movement angles ⒃⑮⑭⑨ of crank (left) ⑩ and (right) ③ during
trimming movement results in an equal angle movements for left and right, against the perpendicular lines ⒕ and ⒖
that are drawn from the center line ⒔ of the two movable knife shafts. Hence, it can be said that the trimming
movement is very light.
[Figure 46]
[Figure 47]
Solenoid
Stroke