Function No. : 072 Function Name : Upper feed plate control when paused
When a pause code occurs, it is to set the operation condition of the upper feed plate.
It keeps the upper feed plate in the lowered position.
[Contents] When the operations is paused, the upper feed plates are all kept in the
lowered position. In this case, the upper feed plates can be controlled with
the pedal.
072. FF PauseCntl
1) CLOSE
Setting
Value
It keeps the upper feed plate in the raised position.
[Contents] When paused during operation, the upper feed plates are all kept in the raised
position. In this case, the upper feed plates can be controlled with the pedal.
2) OPEN
Follow the instructions in 060 : Upper Feed Plate Control When Paused
(Factory installed condition)
[Contents] Follow the instructions in 060 : Upper Feed Plate Control When Paused
3) FF_NUMBER
Function No. : 073 Function Name : Whether to use thread tension adjusting plate after thread trimming.
Define whether to use thread tension adjusting plate after thread trimming.
Do not use thread tension adjusting plate after thread trimming.
[Contents]
073. Trim Hold En
1) DISABLE
Setting
Value
Use thread tension adjusting plate after thread trimming. (Factory Default)
[Contents]
2) ENABLE