Function No. : 074 Function Name : Upper feed plate control
Define whether to use upper feed plate.
Sewing will be allowed when the upper feed plate is opened.
[Contents] In either case of opening or closing the upper feed plate, press the left switch
on the stepping stand to start sewing.
074. Upper Clamp En
1) DISABLE
Setting
Value
Sewing will not be allowed when the upper feed plate is opened. (Factory Default)
[Contents] Only in case of closing the upper feed plate, press the left switch on the
stepping stand to start sewing.
2) ENABLE
Function No. : 075 Function Name : Back/Forth jump stitches
User can define stitch value to move. 1~100[ Stitch ]
[Contents] To confirm the pattern with the back/forth stitch function, the user can set
the stitch value to reduce the time to retrieve stitches.
075. ConKey3 Num
1
Setting
Value
ConKey3 Num=1 [ Before Setting-Up ] ConKey3 Num=3 [ After Setting-Up ]