169
070
Whether to use the function to detect
fall of pressure
1) DISABLE(for 1306)
2) ENABLE
1) Do not use pressure reduction sensor.
2) Use pressure reduction sensor.
1
0/1
Feed control
In case of temporary stop, control
Pan feed plate
Thread tension adjusting after thread
trimming.
071
072
073
0
0~31 See Parameter description related to
general embroidery.
In case of meeting temporary stop code while
embroidering, control top feed plate
1) CLOSE
Put down the top feed plate
2) OPEN
Hold up the top feed plate
3) FF
1) DISABLE
2) ENABLE
Control the top feed plate according to
Article 060
Use thread tension adjusting plate after thread
trimming.
100
068
Reduction speed before work
completion
4
069
Thread trimming delayed time
72[ms] 52~1020[ms]
400[spm]
SPS/C-Series200[spm]
200~500spm
Do not use thread tension adjusting plate after
thread trimming.
NO. Function name Contents
Explanation and factory-installed setting value
Unit
4
4
4
4
4
4
4
4
4
4
1
1
10
10
10
10
10
10
0/1
0~2
1
0~2
1
Waiting time descending completion of presser foot
Waiting time ascending completion of presser foot
Presser Full On Time
Feeding plate Full On Time
Trimming Full On Time
Loosening thread Full On Time
Wiper Full On Time
Left feed plate Full On Time
2 step stroke Full On Time
Inverting device Full On Time
Presser foot Duty
Feeding plate Duty
Trimming Duty
Loosening thread Duty
Wiper Duty
Left feed plate Duty
2 step stroke Duty
Inverting device Duty
Reading order when number of same
pattern data exist in memory
044
045
046
047
048
049
050
051
052
053
054
055
056
063
064
065
067
066
057
058
Extension/Reduction mode
Stitch-NUM:It is not applied
(It is going to apply later)
059
060
061
Number to be performed chain stitch
062
Change of chain number
Reduction stitch before work
completion
Clamp Setting for Chain Sewing
4
4
4
4
Operating time of electype wiper
Returning time of electype wiper
Operating time of air type wiper
Returning time of air type wiper
040
041
042
043
52[ms] 0~1020ms
100[ms] 0~1020ms
(Waiting time for next operation)
100[ms] 0~1020ms
100[ms] 0~1020ms
(Waiting time for next operation)
152[ms] 0~1020ms
152[ms] 0~1020ms
200[ms] 0~1020ms
200[ms] 0~1020ms
200[ms] 0~1020ms
200[ms] 0~1020ms
200[ms] 0~1020ms
200[ms]
0~1020ms
200[ms] 0~1020ms
0~1020ms
33~40%
40~48%
30~80%
30~80%
30~80%
200[ms]
80%, (SPS-1306/SPS-1507/131033)
80%, (SPS-1306/SPS-1507/131043)
50%
50%
50%
30~80%
80%
30~80%
80%
30~80%
80%
The reading order when the same pattern data
numbers exist in the internal memory
1) DISABLE 1) Read first from a floppy disk
2) ENABLE 2) Read first from a internal memory
It settles the way of reduction and extension for pattern
1) DISABLE
Extension and reduction are impossible
2) STITCH_LEN
Extension and reduction by a stitch width
3) STITCH_NUM
Extension and reduction by a number of stitch
0
0~16
0:General sewing, Over 1: Chain sewing
1) MANUAL Automatic change
2) AUTO Manual change by enter key
3) EXTERNAL Change by outward input
2[STITCH], (SPS-5050/80504,
SPS-2211/25165)
1) DISABLE
2) ENABLE
Change to 2~16
Disabled (default)
Enabled