190
1-2) Function description upon using the operating program
If the external input sensor signals explained above are properly connected, the user can automatically call the
designs from #900 to #914 with the sensor signal, and it is possible to use Sewing Start, Clamp, Enter Key, and
Emergency Switch.
To use the function, some parameter functions should be set in advance.
The following is how to set the functions.
<< Main Menu >>
1. Parameter Set
2. Program
3. Bobbin Wind
A.
On the initial screen, press . On Main Menu, select
Parameter Set.
Parameter should be set to use the auto design call
function.
The relevant parameter setting is as follows:
097. Auto Call : Set the auto design call function.
098. Auto Ready : Set the auto ready function after calling a
design.
099. Attach Set : Determine whether to use Sewing Start,
Clamp, Enter Key, and Emergency Switch
or not.
B. Select '097. Auto Call' and move the cursor to 'ENABLE'. Press
ENTER.
C. Conduct the setting for 098 and 099 as above.
D. When the sewing returns to the initial mode, "NOR_SEW" is
changed to "AUTCALL."
E. Use the external input sensor connected by the user.
MODE
< Parameter Set >
097.Auto Call
098.Auto Ready
099.Attach Set
097.Auto Call
1) DISABLE
2) ENABLE <-
3) BARCDE
NO:001 AUTCALL
XS:100%
YS:100% SP:2500
BC:014 PC:0058