© by WilTec Wildanger Technik GmbH Item 50105, 50123, 50977–50980, 50121, 51042–51044 Page 5
http://www.WilTec.de
http://www.aoyue.eu 09 2021-1
http://www.teichtip.de
Application area/functioning
This UVC device ensures clear water for healthy fish. The water is pumped by a pump through the UVC
device. There it flows past the UV lamp and is exposed to UVC radiation. Thus, the bacteria, germs and
floating algae in the water are destroyed, and the water is clarified.
To achieve an optimal result the device should be operated 24 hours in the frost-free seasons.
Commissioning
Switch on the pump and wait until the device is filled with water. Check if all connections are well sealed.
By plugging in the power cable, the device is put into operation.
Technical data
Safety
• This device emits dangerous radiation. Being harmful, direct contact to skin and eyes must be
avoided.
• If the pond filter is damaged, it must not be operated.
• When no water is transported, the device must be switched off.
• By frosty weather, the device must be removed and kept dry in a place free of frost.