Select 107 XLS User Instructions
A timeswitch allows you to set ‘On’ and ‘Off’ time periods. The timeswitch will allow you to set the ‘On’ and
‘Off’ time periods for either Hot water or Central heating to suit your own lifestyle. On some timeswitches you
must also set whether you want the heating or hot water to run continuously, run under the chosen ‘On’ and
‘Off’ heating periods, or be permanently off.
The time on the timeswitch must be correct. Some types have to be adjusted in spring and autumn at the
changes between Greenwich Mean Time and British Summer Time.
You may be able to temporarily adjust the heating programme, for example, ‘Override’, ‘Advance’ or ‘Boost’.
These are explained in the manufacturer’s instructions.
The heating will not work if the room thermostat has switched the heating off. And, if you have a hot-water
cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the
correct temperature.
SELECT 107XLS
USER INSTRUCTIONS
INTRODUCTION
The SELECT 107 XLS electronic timeswitch can automatically switch ON and OFF, up to 3 times a day, at
whatever times you choose.
During installation, the installer selects 24 hour, or 5 day/2 day, or 7 day programming and 2 or 3 on/off
periods per day, via a 4 position DIP switch on the back of the unit (see installation instructions).
Question and Answer IconNeed help?

Do you have a question about the Sunvic 107 XLS and is the answer not in the manual?

Sunvic 107 XLS Specifications

General IconGeneral
BrandSunvic
Model107 XLS
CategorySwitch
LanguageEnglish

Summary

INTRODUCTION

SELECTING OPERATING MODE

ON Mode

Switch will be on continuously.

AUTO Mode

Switch will be switched On or Off as programmed.

ALLDAY Mode

Switch will be switched On only once each day.

OFF Mode

Switch will be continuously OFF.

Setting the Time and Date

CHANGING PROGRAMME TIMES

Setting Programme Periods

Procedure to set ON/OFF times for up to three periods per day.

Day Programmer Types

Explains 7-day, 5-day/2-day, and 24-hour programming options.

Using the COPY Function

How to copy programmed times to subsequent days or day groups.

USING ADVANCE

+1hr Function

Temporarily extends programme or switches on for 1 hour.

POWER INTERRUPTION AND RESET

Power Interruption

Programmer retains time and programme during mains failure.

Reset Button

Restores built-in programme and resets time and date.

BUILT IN PROGRAMME

Installation Instructions

Pre Installation set-up

Configure the unit using DIP switches before installation.

Fitting Wall Plate

Detailed steps for mounting the wall plate.

Wiring and General Installation

Mains supply, wiring connections, and general installation steps.

Direct Upgrade

Steps for replacing an old timeswitch.

TIME SWITCH TERMINAL COMPARISONS