116
conditioning
expansion valve partial clogged
wash
expansion valve fault
replace
dry bottle clogged
replace
appearance of dustproof net or evaprator is too
dirty
wash
return air inlet of A/C is clogged
clean
appearance of condenser is too dirty
wash
compressor fault
repair or replace
misuse manipulator, opened heating equipment
close warm mode
hot water flow controller/ solenoid warm water
valve fault or it jamed at the open position
Wash or replace
warm water valve is open
close warm up valve
manipulator fault can not control hot water flow
controller/solenoid warm valve closed
replace
can not heating
or insufficient
heating
water temprature of engine is too low
use it when water temperature of
engine is rising
manipulator fault can not control hot water flow
controller/ solenoid warm water valve opened
replace
hot water flow controller/ solenoid warm water
wire line fault
Repair or replace
warm water flow controller/ solenoid warm water
valve fault or warm water valve jamed at the
closed position or samll position
replace
warm water valve closed or opened a little
turn up warm water valve
manipulator heat setting is too little
magnify heating capacity setting
manipulator/ misuse control panel, opened
refrigeration
close refrigeration mode/A/C
switch
surface of dustproof net is too dirty
wash
return air inlet of A/C is clogged
clean