SUPAIR | STRIKE 2 | page 14
Thank you for reading the following carefully ! We recommend for the initial rescue parachute assembly and installation to be made
by a qualified professional. Reserve parachute folding and installation inside the harness must conform to the specific guidelines
found in this manual. We are not responsible for any other use.
The volume of reserve parachutes may vary depending on the folding
We have checked the pocket for compatibility with some of our reserve parachutes. Other parachutes are compatible, which we
have not tested here.
Flaps fastened with a cable
Volume 4,5 to 4,75 liters
Adapted to the reserve parachutes SU-
PAIR, SHINE, and FLUID LIGHT as well as
other rescue solo models.
1 2
INSTALLING THE RESERVE PARACHUTE
Connecting the handle to the POD
Rescue parachute pocket characteristics
Fasten the reserve parachute handle bridle to the
middle pod loop via a Lark’s head knot connection.
Tighten the handle/POD
connection securely.
STRIKE 2 Sizes L and XL
Compatible
parachutes
S M L
SHINE
FLUID LIGHT
STRIKE 2 Sizes S and M
Compatible
parachutes
S M L
SHINE *
FLUID LIGHT