43
Chapter 2: Installation
Power Button
OH/Fan Fail LED
1
NIC1 Link Active LE
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
P3V3
UID LED
Ground
Ground
P3V3
NC
Ground
SW_NMI_N
NC
NIC2 Link Active LE
P3V3_STBY
P3V3_STBY
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11
and 12 of JF1, and the LED connection for LAN port 2 is on pins 9 and 10. Attach the NIC
LED cables here to display network activity. Refer to the table below for pin denitions.
LAN1/LAN2 LED
Pin Denitions (JF1)
Pin# Denition
9 NIC 2 Activity LED
10 NIC 2 Link LED
11 NIC 1 Activity LED
12 NIC 1 Link LED
HDD LED/UID Switch
The HDD LED/UID Switch connection is located on pins 13 and 14 of JF1. Attach a cable to
pin 14 to show hard drive activity status. Attach a cable to Pin 13 to use UID switch. Refer
to the table below for pin denitions.
HDD LED
Pin Denitions (JF1)
Pin# Denition
13 3.3V Stdby/UID_SW
14 HDD Active
1. NIC2 LED
2. NIC1 LED
3. HDD LED / UID Switch
1
2
3