EasyManua.ls Logo

Supera Pureline M6000 - User Manual

Supera Pureline M6000
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OXYGEN CONCENTRATORS
M6000 & M6100
Operators Manual
Supera , LLC Copyright 2021
For Veterinary Use Only
Model M6000
*Shown with optional vaporizer
Model M6100
*Shown with optional vaporizer

Questions and Answers

Summary

Examination and Preparation for Use

Machine Assembly

Attaching the top assembly to frame

Instructions for securing the main assembly to the frame using screws.

Mounting the oxygen concentrator

Steps to mount the oxygen concentrator unit onto the machine's frame.

Connecting the supply hose

Guidance on connecting the oxygen supply hose to the concentrator.

General Safety Guidelines

Warnings

Potential hazardous situations that could result in serious injury or death if not avoided.

Cautions

Potentially hazardous situations that could result in property damage or minor injury.

Unpacking and Packaging

Front Panel Overview

I;O (ON;OFF) switch

The main power switch to turn the device on and off.

Indicator lights

Lights that provide status information about the device operation.

Oxygen product outlet

The port where oxygen-enriched air exits the device.

Circuit breaker

Protects the device from electrical overloads.

Pre-set flow meter

Displays and sets the oxygen flow rate, but cannot be adjusted.

Device Operation Procedures

Turning the device on

Connect power cable and press the power switch to activate.

Turning the device off

Procedure for safely shutting down the oxygen concentrator.

Cleaning and Maintenance

Exterior cleaning guidelines

Guidelines for cleaning the outside surfaces of the concentrator.

Filter maintenance and replacement

Procedures for cleaning and replacing air filters for optimal performance.

Internal Maintenance and Spare Parts

No internal maintenance required

Statement that internal maintenance is not required and voids warranty.

Accessories and spare parts requirements

Requirements for accessories and spare parts used with the O2 concentrator.

Materials in contact with output

List of materials that come into contact with the oxygen output.

Operating principle

Explanation of how the oxygen concentrator produces oxygen.

Alarms, Safety Devices, and Indicators

Process fault alarms

Information on process faults, audible and visual alarms.

Oxygen concentration alarms

How low oxygen concentration triggers alarms and indicator changes.

Safety devices overview

Overview of safety mechanisms like compressor motor thermal protection.

Indicator light functions

Explanation of the green and red indicator lights and their meanings.

OCSI Function and Technical Characteristics

OCSI operating principle

How the oxygen monitor checks concentration and activates alarms.

Alarm maintenance

Information on the maintenance requirements for device alarms.

Device dimensions and weight

Specifications including dimensions, weight, and noise level.

Oxygen Concentration USP93%

Performance data for oxygen concentration at different flow rates.

Electrical Power and Environmental Specifications

Electrical Power Supply Details

Electrical specifications including voltage, frequency, and power consumption.

Air Filters and Circulation

Location and type of air filters, and description of the cooling fan.

Environmental Operating Conditions

Operating and storage conditions for temperature, humidity, and altitude.

Compliance and Maintenance Guidance

Applicable Safety Standards

Relevant safety and compatibility standards (IEC, CSA).

Preventive Maintenance Schedule

Routine tasks for filter cleaning/replacement and concentration checks.

Troubleshooting

Device does not operate

Troubleshooting steps for when the device fails to power on or operate.

Audible alarm sounds intermittently

Possible causes and solutions for intermittent audible alarms.

Red light remains lighted

Troubleshooting steps for when the red indicator light stays on.

Alarm test does not work

Issues related to the alarm test function and potential causes.

Green indicator is not lighted

Solutions for when the green indicator light does not illuminate.

No flow, audible alarm sounds continuously

Troubleshooting when there is no flow and a continuous audible alarm.

Flow present, audible alarm sounds continuously

Addressing issues with flow and continuous audible alarms.

Compressor stops mid-cycle

Troubleshooting the compressor stopping and restarting intermittently.

Safety Pop Off Valve

Normal Operation

How to operate the safety pop-off valve during normal breathing.

User Error Safety (pop off valve left closed)

The effect of leaving the pop-off valve closed and its safety implications.

Manual Ventilation

Using the pop-off valve for manual ventilation and pressure management.

Machine Leak Test

Leak Test Procedure

Step-by-step instructions for performing a machine leak test.

Auxiliary & Main Oxygen Switch

MAIN Switch Position

How the switch in the 'MAIN' position affects oxygen supply.

AUXILARY Switch Position

How the switch in the 'AUX' position affects oxygen supply.

Accessories

I.V. Pole (included)

Information about the included I.V. pole accessory.

Optional universal control arm

Description of the optional universal control arm for Bain circuits.

Safety pop off valve accessory

Details on the safety pop off valve accessory.

Regular pop off valve accessory

Details on the regular pop off valve accessory.

Features & Accessories

Bag & circuit organizer

Description of the bag and circuit organizer accessory.

Optional F-Air evacuation kit

Information on the optional F-Air evacuation kit.

Waste Gas Evacuation

Waste gas interface valve P;N EVC630

Details on the waste gas interface valve for fan-based systems.

Waste gas interface valve P;N EVC629

Details on the waste gas interface valve for vacuum pump systems.

Non-Rebreathing Modified Jackson-Rees Circuits

Connection Instructions

Steps for connecting the non-rebreathing circuit to the anesthesia machine.

Rebreathing Unilimb Circuits

CIR529 & CIR529 P Circuit Description

Details on the unilimb rebreathing circuits and their patient suitability.

Maintenance

Anesthesia Machine Servicing

Requirements for servicing the anesthesia machine by certified technicians.

Annual Preventative Maintenance Service

Components and procedures included in the annual preventative maintenance.

Daily Inspection - Leak Test

Daily checks required before use, focusing on leaks.

Oxygen Concentrator Filter Maintenance

Procedures for cleaning and replacing oxygen concentrator filters.

Warranty; Return Policy

Supera LLC Limited Warranty

Details of the limited warranty offered by Supera LLC.

Specific Exclusions from this Warranty

List of conditions and items not covered by the Supera Limited Warranty.

For Warranty Service

Contact information and procedures for obtaining warranty service.

Shipping Policies

Inspect Box and Document Shipment

Procedures for inspecting the shipment upon arrival and documenting damage.

Handling Damaged Shipments

Instructions for refusing or reporting damaged goods and packaging.

Documentation

Machine Service Information

Fields for recording machine service dates and information.

Summary

Examination and Preparation for Use

Machine Assembly

Attaching the top assembly to frame

Instructions for securing the main assembly to the frame using screws.

Mounting the oxygen concentrator

Steps to mount the oxygen concentrator unit onto the machine's frame.

Connecting the supply hose

Guidance on connecting the oxygen supply hose to the concentrator.

General Safety Guidelines

Warnings

Potential hazardous situations that could result in serious injury or death if not avoided.

Cautions

Potentially hazardous situations that could result in property damage or minor injury.

Unpacking and Packaging

Front Panel Overview

I;O (ON;OFF) switch

The main power switch to turn the device on and off.

Indicator lights

Lights that provide status information about the device operation.

Oxygen product outlet

The port where oxygen-enriched air exits the device.

Circuit breaker

Protects the device from electrical overloads.

Pre-set flow meter

Displays and sets the oxygen flow rate, but cannot be adjusted.

Device Operation Procedures

Turning the device on

Connect power cable and press the power switch to activate.

Turning the device off

Procedure for safely shutting down the oxygen concentrator.

Cleaning and Maintenance

Exterior cleaning guidelines

Guidelines for cleaning the outside surfaces of the concentrator.

Filter maintenance and replacement

Procedures for cleaning and replacing air filters for optimal performance.

Internal Maintenance and Spare Parts

No internal maintenance required

Statement that internal maintenance is not required and voids warranty.

Accessories and spare parts requirements

Requirements for accessories and spare parts used with the O2 concentrator.

Materials in contact with output

List of materials that come into contact with the oxygen output.

Operating principle

Explanation of how the oxygen concentrator produces oxygen.

Alarms, Safety Devices, and Indicators

Process fault alarms

Information on process faults, audible and visual alarms.

Oxygen concentration alarms

How low oxygen concentration triggers alarms and indicator changes.

Safety devices overview

Overview of safety mechanisms like compressor motor thermal protection.

Indicator light functions

Explanation of the green and red indicator lights and their meanings.

OCSI Function and Technical Characteristics

OCSI operating principle

How the oxygen monitor checks concentration and activates alarms.

Alarm maintenance

Information on the maintenance requirements for device alarms.

Device dimensions and weight

Specifications including dimensions, weight, and noise level.

Oxygen Concentration USP93%

Performance data for oxygen concentration at different flow rates.

Electrical Power and Environmental Specifications

Electrical Power Supply Details

Electrical specifications including voltage, frequency, and power consumption.

Air Filters and Circulation

Location and type of air filters, and description of the cooling fan.

Environmental Operating Conditions

Operating and storage conditions for temperature, humidity, and altitude.

Compliance and Maintenance Guidance

Applicable Safety Standards

Relevant safety and compatibility standards (IEC, CSA).

Preventive Maintenance Schedule

Routine tasks for filter cleaning/replacement and concentration checks.

Troubleshooting

Device does not operate

Troubleshooting steps for when the device fails to power on or operate.

Audible alarm sounds intermittently

Possible causes and solutions for intermittent audible alarms.

Red light remains lighted

Troubleshooting steps for when the red indicator light stays on.

Alarm test does not work

Issues related to the alarm test function and potential causes.

Green indicator is not lighted

Solutions for when the green indicator light does not illuminate.

No flow, audible alarm sounds continuously

Troubleshooting when there is no flow and a continuous audible alarm.

Flow present, audible alarm sounds continuously

Addressing issues with flow and continuous audible alarms.

Compressor stops mid-cycle

Troubleshooting the compressor stopping and restarting intermittently.

Safety Pop Off Valve

Normal Operation

How to operate the safety pop-off valve during normal breathing.

User Error Safety (pop off valve left closed)

The effect of leaving the pop-off valve closed and its safety implications.

Manual Ventilation

Using the pop-off valve for manual ventilation and pressure management.

Machine Leak Test

Leak Test Procedure

Step-by-step instructions for performing a machine leak test.

Auxiliary & Main Oxygen Switch

MAIN Switch Position

How the switch in the 'MAIN' position affects oxygen supply.

AUXILARY Switch Position

How the switch in the 'AUX' position affects oxygen supply.

Accessories

I.V. Pole (included)

Information about the included I.V. pole accessory.

Optional universal control arm

Description of the optional universal control arm for Bain circuits.

Safety pop off valve accessory

Details on the safety pop off valve accessory.

Regular pop off valve accessory

Details on the regular pop off valve accessory.

Features & Accessories

Bag & circuit organizer

Description of the bag and circuit organizer accessory.

Optional F-Air evacuation kit

Information on the optional F-Air evacuation kit.

Waste Gas Evacuation

Waste gas interface valve P;N EVC630

Details on the waste gas interface valve for fan-based systems.

Waste gas interface valve P;N EVC629

Details on the waste gas interface valve for vacuum pump systems.

Non-Rebreathing Modified Jackson-Rees Circuits

Connection Instructions

Steps for connecting the non-rebreathing circuit to the anesthesia machine.

Rebreathing Unilimb Circuits

CIR529 & CIR529 P Circuit Description

Details on the unilimb rebreathing circuits and their patient suitability.

Maintenance

Anesthesia Machine Servicing

Requirements for servicing the anesthesia machine by certified technicians.

Annual Preventative Maintenance Service

Components and procedures included in the annual preventative maintenance.

Daily Inspection - Leak Test

Daily checks required before use, focusing on leaks.

Oxygen Concentrator Filter Maintenance

Procedures for cleaning and replacing oxygen concentrator filters.

Warranty; Return Policy

Supera LLC Limited Warranty

Details of the limited warranty offered by Supera LLC.

Specific Exclusions from this Warranty

List of conditions and items not covered by the Supera Limited Warranty.

For Warranty Service

Contact information and procedures for obtaining warranty service.

Shipping Policies

Inspect Box and Document Shipment

Procedures for inspecting the shipment upon arrival and documenting damage.

Handling Damaged Shipments

Instructions for refusing or reporting damaged goods and packaging.

Documentation

Machine Service Information

Fields for recording machine service dates and information.

Supera Pureline M6000 Specifications

General IconGeneral
CategoryMedical Equipment
ModelM6000
ApplicationMedical
Power SupplyAC 100-240V, 50/60Hz
Operating Temperature10°C
Humidity30% RH
Safety StandardsIEC 60601-1

Related product manuals