38
English
PROBLEM CAUSE SOLUTION
Exhaust outlet temperature warning
"
MASS tEMP
"
Blocked flue
Clean flue
D
efective electronic board
Replace electronic board (use only
original spares)
D
efective sensor
R
eplace sensor (use only original
spares)
Badly positioned sensor
Check positioning and connection of
sensor (see electrical diagram)
Incorrect settings input
C
heck settings
Smoke sensor disconnected
"
NO CONN"
Bad connection from 2-pin terminal
to electronic board
Check positioning and connection
of sensor (see electrical diagram)
Defective electronic board
Replace electronic board (use only
original spares)
Badly positioned sensor
Check connections
Stove runs for 9-10 minutes then
goes out
The heat sensor is blocked
Retry and if problem persists con-
tact an authorised technician
Exhaust fumes have not reached
required temperature
Retry and if problem persists contact
an authorised technician
Heat sensor badly connected
Check cabling and connections
Blocked flue
Clean flue
Failed ignition
See "
NO ACC
"
Defective electronic boar
d
Replace electronic board (use only
original spar
es)
Fuel-loading system blocked
Empty fuel tank; check and clean fuel-
loading system
This instruction booklet contains all the useful information for installation, operation and maintenance.