46
Super X11SCL-F User's Manual
Standby Power
The Standby Power header is located at JSTBY1 on the motherboard. You must have a card
with a Standby Power connector and a cable to use this feature. Refer to the table below
for pin denitions.
Standby Power
Pin Denitions
Pin# Denition
1 +5V Standby
2 GND
3 NC
IPMI CODE
BAR CODE
DESIGNED IN USA
MAC CODE
MEGERAC
LICENSE
+
+
ASpeed
AST2500
Intel
C242
Intel
i210
VGA
JD1
CPU SLOT4 PCI-E 3.0 X4(IN X8)
CPU SLOT6 PCI-E 3.0 X8(IN X16)
CPU SLOT5 PCI-E 3.0 X4(IN X8)
JSTBY1
JTPM1
JPWR1
JF1
I-SATA4
I-SATA5
I-SGPIO2
I-SGPIO1
JPWR2
JPI2C1
FAN4
FAN3
FAN2
FAN1
FANA
JIPMB1
JSD1
JSD2
BT1
JL1
SP1
MH11
MH10
JUIDB1
LE1
LEDBMC
LE3
LEDPWR
JBT1
I-SATA0
I-SATA3
I-SATA2
I-SATA1
JPG1
JOH1
X11SCL-F
REV:1.01
DIMMA2
DIMMA1
DIMMB2
DIMMB1
USB10(3.0)
USB8/9(3.0)
USB4/5
USB2/3
COM1
USB0/1
IPMI_LAN
USB6/7(3.0)
LAN2
CPU
NMI
JF1
LED
PWR
X
LED
HDD
NIC
LED
UID
2
NIC
1
RST
PWR
ON
FAIL
PS
M.2 PCI-E 3.0 X4
COM2
LAN1
JPME2
JWD1
1. Standby Power Header
2. Overheat/Fan Fail LED
Header
1
Overheat/Fan Fail LED Header
The JOH1 header is used to connect an LED indicator to provide warnings of chassis
overheating and fan failure. This LED will blink when a fan failure occurs. Refer to the tables
below for pin denitions.
Overheat LED Header
Status
State Denition
Solid Overheat
Blinking Fan Fail
Overheat LED
Pin Denitions
Pin# Signal
1
Pull high to +3.3V
power through 330-ohm
resistor
2 OH Active
2

Table of Contents