54
Super X12DAi-N6 User's Manual
Power Button
(Blue LED_Cathode_UID)
NIC1 (Activity) LED
Reset Button
HDD LED
FP PWR LED
ID_UID/3.3V Stby
Ground
Ground
1 2
Ground
Power Fail (for LED6)
NIC2 (Link) LED
NMI
3.3V
(Red OH/Fan Fail/PWR Fail for LED5/Blue UID LED)
3.3V
Red+ Blue+
NIC2 (Activity) LED
NIC1 (Link) LED
Key
Key
1
2
1. Power Button
2. Reset Button
Reset Button
Pin Denitions (JF1)
Pin# Denition
3 Reset
4 Ground
Power Button and BIOS/BMC Status LED
Indicator
Pin Denitions (JF1)
Pin# Denition
1 Signal
2 Ground
Power On and BMC/BIOS Status LED Button
The Power On and BMC/BIOS Status LED button is located on pins 1 and 2 of JF1.
Refer to the tables below for more information.
Reset Button
The Reset button is located on pins 3 and 4 of JF1. Momentarily contacting both pins will
Power Button
LED States
Status Event
Green: solid on System power on
BMC/BIOS blinking green @ 4Hz BMC/BIOS checking
BIOS blinking green @ 4Hz BIOS recovery/update in progress
BMC blinking red x2 (2 blinks red) @ 4Hz, 1 pause @ 2Hz (on-on-o-o) BMC recovery/update in progress
BMC/BIOS blinking green @ 1Hz Flash not detected or golden image
checking failure