1. Align PEEK nut A, which is next to the triangle (Pin 1) on the heatsink, against the
threaded fastener a on the CPU socket. Then align PEEK nuts B, C, and D on the
heatsink against threaded fasteners b, c, and d on the CPU socket, making sure that
all PEEK nuts on the heatsink are properly aligned with the correspondent threaded
fasteners on the CPU socket.
2. Once they are aligned, gently place the heatsink on top the CPU socket, making sure
that each PEEK nut is properly attached to its corresponding threaded fastener.
Installing the PHM into the CPU Socket
A, B, C, D:
PEEK Nut on the Heatsink
a, b, c, d:
Threaded Fastener on
the CPU socket
A
C
D
B
a
b
d
c
A, B, C, D:
PEEK Nut on the Heatsink
a, b, c, d:
Threaded Fastener on
the CPU socket
A
C
D
B
a
b
d
c
Air Flow Direction