EasyManua.ls Logo

Suunto CB-71/STD - Operating and Storage Temperatures; Technical Specifications

Suunto CB-71/STD
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Operating and Storage Temperatures
SM-16 Operating temperature 0° C to 40° C [32° F to 104° F]
Storage temperature -20° C to 50° C [-4° F to 122° F]
SM-36 Operating and storage temperature 0° C to 40° C [32° F to 104° F]
Technical Speci cations
The Suunto depth gauge SM-16 complies with the prEN 13319 standard.
The tolerances for depth gauges are:
At 3m +0.8 / -0.4 m
At 6m +0.8 / -0.4 m
At 9m ±0.8 m
At 15m +1/ -1.2 m
At 30m +1/ -1.2 m
At 45m +1/ -1.5 m
At 60m +1 / -1.5 m
The SM-36 pressure gauges comply with the EN 250 standard.
The tolerances for pressure gauges, measured at decreasing pressure are:
At 40 bar ± 5 bar
At 100 bar ± 10 bar
At 200 bar ± 10 bar
At 300 bar ± 10 bar