16
In case the transmitter battery is running low, a low battery warning
“LOBT” will be transmitted and displayed intermittently with the pressure
reading on the Vytec (Fig.2.6 d).
If the dive is started without that the Vytec and the transmitter have been
properly paired, the Vytec will indicate that no cylinder data is available
by displaying “OFF” (Fig. 2.6 e).
TABLE 2.1. PRESSURE TRANSMISSION RELATED DISPLAYS
Display Indication Figure 2.6
SETC Set Code. No code stored,
wrist unit ready for pairing with transmitter. a
- - - Pressure reading over 360 bar [5220 psi] b
FAIL Indicates pressure reading has not been
updated in more than 1 minute.
Transmitter is out of range, in power saving
mode or on another channel. Activate the
transmitter by breathing off the regulator,
and recode the wrist unit if necessary. c
LOBT Indicates pressure transmitter battery voltage d
is low. Change the transmitter battery!
OFF Pairing has not been conducted before e
start of dive. No cylinder data available.